BD SurePath™ Pap Test


The time is right for the BD SurePath™ test.
BD SurePath™ liquid-based Pap test  

“Keeping collecting device in liquid medium is mandatory to ensure optimized liquid-based cervical cytologic sampling”
G Bigras, M Rieder, J Lambercy, B Kunz, J Chatelain, O Reymond, D Cornaz
Journal of Lower Genital Tract Disease, Vol 7(3), 2003: 168-174

OBJECTIVE
To determine the impact of not keeping collecting device in liquid-based cytology. Loss of material was computed from a pair of subsamples from the same cervical scrape. One subsample was obtained by rinsing the collecting device in one vial and the other by discarding it in another vial. Homogeneity of subsamples was assessed between subsamples.

MATERIALS AND METHODS
Loss of material was analyzed with a two-way analysis of variance whose two factors were G (five gynecologists) and R (number of rinsing rotations in the first vial). Endocervical clusters were counted on slides prepared from all subsamples.

RESULTS
On average, 37% of cellular material is lost when the collecting device is discarded. Loss of material is different among gynecologists. The more intense the rinsing process the less the loss, but the latter is never zero and is poorly predictable. The discarded subsample often contains a greater amount of endocervical clusters.

CONCLUSIONS
Discarding collecting device in liquid-based cytology reproduces one of the flaws of the conventional smear technique. Losing cellular material may have an impact on cervical cancer detection, but this still has to be evaluated with further investigations.

Mean Loss of Cellular Material Using a Rinsing Method

 
 
Clinical News

Independent study on the effect of blood on cellularity of cervical sample.

BD SurePath™ Pap test Direct to Vial Clinical Study.

Study shows that rinsing sampling devices does not transfer all the sampled cervical cells to the vial for analysis.

 

Unless otherwise noted, BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company. © 2014 BD