BD Vacutainer® CPT™ Cell Preparation Tube with Sodium Heparin

Reagents, Supplies & Testing

Reagents Provided:

  1. Reorder No. 362753
    8 mL Draw Capacity (16 x 125mm Tube Size)
    Sterile Tube Interior
    Contains:
    • Minimum of 120 USP Units of Sodium Heparin in 1.0 mL of Phosphate Buffered Saline Solution (Top Fluid Layer)
    • 3.0 gm of Polyester Gel (Middle Layer)
    • 2.0 mL of Polysaccharide Sodium Diatrizoate Solution (FICOLL™ HYPAQUE™ solution, Bottom Fluid Layer)
    • Silicone Coated Glass Tube
    • Silicone Lubricated Rubber Stopper

Reagents Not Provided:

  1. Reagent
    • Phosphate Buffered Saline (PBS) without Ca++ or Mg++.

Supplies and Equipment Not Provided:

  1. Specimen Collection
    • Vacutainer® Brand Holder and Vacutainer® Brand Needle or Vacutainer® Brand Blood Collection Set.
    • Alcohol Swab.
    • Dry Sterile Gauze.
    • Tourniquet.
    • Adhesive Bandage.
    • Gloves appropriate for the protection of the person collecting specimen.
    • Sharps disposal system.
  2. Specimen Processing
    • 15 mL Size Plastic Conical Centrifuge Tubes with Caps.
    • Pasteur Pipettes.
    • Centrifuge with Swinging Bucket Rotor and Tube Carriers/Adapters for 16 x 125mm Tube Size.
      NOTE: Centrifuge must be capable of generating at least 1500 RCF at the Tube bottom.
    • Gloves appropriate for the protection of the person processing specimen.

FICOLL is a trademark of Amersham Biosciences AB
HYPAQUE is a trademark of Amersham Health AS


About BD Vacutainer® CPT™ Cell Preparation Tube with Sodium Heparin

Intended Use

Summary & Explanation

Test Principles

Reagents, Supplies & Equipment

Warnings & Precautions

Venipuncture Technique

Procedure

Limitations

Expected Results

Performance Characteristics

Troubleshooting

Product Insert [PDF]

References

How To Order

Contact Us

More Molecular Diagnostics & Proteomics products



 

[spacer image]
[spacer image] [spacer image] [spacer image]
[spacer image] [spacer image] [spacer image]
[spacer image]