BD Nexiva closed IV catheter system

Preserving sites and protecting veins

The BD Nexiva IV catheter, shown to preserve sites for longer and designed to protect patients by reducing the risk of complications and restarts. 1,2*

BD IV technologies can help provide significantly better care and experience for your patients, efficiently and cost effectively. 1

BD Vialon biomaterial

Proprietary BD Vialon biomaterial softens up to 70% in the vein, enabling longer dwell times 3† and reducing the chance of mechanical phlebitis by up to 50%. 3†

BD Instaflash needle technology

Provides quick blood visualization that may help improve insertion success and therefore reduce insertion attempts.

Built-in stabilization platform

Reduces dislodgement by 84% and complies with the Infusion Therapy Standards of Practice and CDC guidelines for catheter stabilization. 4,5

Pre-attached extension set

Shown to significantly reduce blood exposure during insertion compared to an open system 2* and aligns with INS guidelines. 4

Centers for Disease Control and Prevention

Catheter stabilization is recognized as an intervention to decrease the risk for phlebitis, catheter migration and dislodgement and may be advantageous in preventing catheter-related bloodstream infections (CRBSIs).3


Infusion Therapy Standards of Practice

Recommend limiting the use of add-on devices to reduce the potential for contamination, additional manipulation, and disconnection.5


Increased clinician safety

98% reduced blood exposure during insertion due to the BD Nexiva IV catheter preassembled system.2*


Increased catheter stabilization

Clinically demonstrated to reduce accidental dislodgement,2‡ meeting Infusion Nursing Society standards4 and CDC guidelines5 for catheter stabilization.


Reduced rate of complications

In a clinical study, results demonstrated a significant reduction in the rate of phlebitis (grade 2 or higher), PIVC-related complications, and infiltration in the closed system versus the open system group.1


Preserves sites

In compliance with industry best practices, BD Nexiva IV catheter is the only all-in-one PIVC system shown to dwell longer and preserve sites vs open system PIVCs.1,2||


Related Videos

Related Products


Traditonal vs closed insertion

Watch this video to learn more about the difference between using a traditional IV catheter vs a closed IV catheter system for catheter insertion.


Notes

*Compared to an open system.

**Results and savings may vary for other institutions.

†Compared with an FEP catheter.

‡When used with a specially designed 3M Tegaderm IV site securement dressing.

§Compared with B. Braun Introcan Safety ® catheter with Bard Statlock ® IV Ultra stabilizatio device.

||Compared with 96 hours in an open system.

Compared with a non-blood control catheter.

References
  1. González López J, Arribi Vilela A, Fernández Del Palacio E, et al. Indwell times, complications and costs of open vs closed safety peripheral intravenous catheters: a randomized study. J Hosp Infect. 2014;86(2):117-126.
  2. Bausone-Gazda D, Lefaiver CA, Walters SA. A randomized controlled trial to compare the complications of 2 peripheral intravenous catheter stabilization systems. J Infus Nurs. 2010;33(6):371-384.
  3. Maki DG, Ringer M. Risk factors for infusion-related phlebitis with small peripheral venous catheters. Ann Intern Med. 1991;114(10):845-854.
  4. Infusion Nurses Society. Infusion therapy standards of practice. J Infus Nurs. 2016:39(1S).
  5. O’Grady NP, Alexander M, Burns LA, et al. Guidelines for the prevention of intravascular catheter-related infections. CDC. 2011:16.

This site uses cookies. If you click accept cookies then all cookies will be written. Please review our cookies policy and configure your cookies for your experience.