BD Phoenix panels

Accurate and rapid susceptibility results

The BD Phoenix system offers a variety of identification only, susceptibility only and combination of identification and susceptibility panels. BD Phoenix panels provide accurate, rapid identification and antimicrobial susceptibility testing results for most clinically significant aerobic and facultative anaerobic Gram-negative and Gram-positive bacteria, as well as identification of yeast and yeast-like organisms.

Trusted performance

The BD Phoenix system provides on-panel doubling dilutions and built-in detection resistance, including CPO, MRSA, mecA, VRSA, VRE, ESBL, HLAR, and iMLSb*.

Ease of use

BD Phoenix panels can be stored at room temperature, are leak-resistant and do not require reagent additions post inoculation.

Emerging resistance detection

The BD Phoenix Emerge Gram-negative and Gram-positive panels offer 136 wells for susceptibility testing, allowing for additional antimicrobial dilutions that help provide the foundation for detecting emerging resistance. 

Detecting Carbapenamase producing organisms (CPOs)

The BD Phoenix CPO detect test, offered on certain Gram-negative panels, provides results, including Ambler classification that can support clinicians in making treatment decisions.

Dual growth detection technology

BD Phoenix panels allow the BD Phoenix M50 instrument to determine growth using both an oxidation-reduction reaction and turbidity development, providing both rapid and accurate susceptibility results.


True doubling dilutions

The BD Phoenix system utilises on-panel doubling dilutions of antimicrobial concentrations for determination of MIC results.


Multiple panel formats

BD Phoenix panels, which require no refrigeration and are leak resistant, are available in a variety of formats including identification-only and susceptibility-only, and in combination identification and susceptibility panels.


Largest number of wells per panel

With 136 wells dedicated to susceptibility testing, the BD Phoenix Emerge panel may allow for additional antimicrobial dilutions or additional drugs.


Resistance detection

The BD Phoenix system provides on-panel doubling dilutions of antimicrobials and built-in detection of resistance, including CPO, MRSA, mecA, VRSA, VRE, ESBL, HLAR, and iMLSb*.

*Depending on BD Phoenix panel type and organism identification.


Automated panel inoculation preparation

The BD Phoenix AP automated inoculation preparation instrument may help to reduce sample preparation workflow burdens, reducing total hands-on time per sample by 50% compared to manual BD Phoenix.1


Microorganism identification

  • The BD Phoenix system offers identification-only panels and combination ID/AST panels, using 51 wells for identification substrates.
  • The instrument can provide identification of most clinically significant Gram-negative and Gram- positive bacteria, as well as yeast.

Susceptibility testing

  • The BD Phoenix system offers 85 wells for antimicrobial dilutions on standard AST-only panels and combination ID/AST panels, and 136 wells on the BD Phoenix Emerge panel.
  • The instrument can provide susceptibility results for most clinically significant Gram-negative and Gram-positive bacteria.
  • The BD Phoenix system panels test for several resistance markers* such as** :
    • Gram-positive bacteria
      • HLAR—High Level Aminoglycoside Resistant Enterococcus
      • iMLSb—Inducible Clindamycin Resistance
      • MRSA—based on Oxacillin Interpretation with Staphylococcus species
      • mecA - detection in mecA-mediated resistance Staphylococcus aureus
      • BL-Staphylococcus ß-Lactamase (Nitrocefin-based test)
      • VRSA—Vancomycin-Resistant Staphylococcus aureus
      • VRE—based on Vancomycin interpretation
    • Gram-negative bacteria
      • CPO—Carbapenemase Producing Organism
      • ESBL—offered on Gram-negative panels and requires no additional disc diffusion or E-Test confirmation

* Depending on BD Phoenix panel type and organism identification.

Detecting CPOs

  • The BD Phoenix CPO detect test, available on certain BD Phoenix Gram-negative panels, provides information, including Ambler classification, to help guide clinicians in their treatment decisions.
  • This test is available in two-panel configurations that allow microbiology labs to test for CPOs as part of routine susceptibility testing on BD Phoenix panels:
    • 2-well configuration—provides detection of Carbapenemase-producing organisms in Enterobacterales, Pseudomonas aeruginosa and Acinetobacter baumannii
    • 9-well configuration—provides detection of Carbapenemase-producing organisms and Ambler classification (A, B or D) in Enterobacterales, Pseudomonas aeruginosa and Acinetobacter baumannii
  • The BD Phoenix CPO detect test is currently the only phenotypic test on an automated AST system that provides CPO detection and Ambler classification.
  • On average, the BD Phoenix CPO detect test detects and classifies CPOs from isolated colonies within 6 to 11 hours**.

**BD internal studies—data on file

BD Phoenix identification panels
Catalogue no. Description Quantity (shelf pack)
448007 BD Phoenix NID panel 25
448008 BD Phoenix PID panel 25
448316 BD Phoenix yeast ID panel 25

BD Phoenix identification and susceptibility panels
Catalogue no. Description Quantity (shelf pack)
448444 BD Phoenix PMIC/ID-93 25
448445 BD Phoenix UNMIC/ID-416 25
448616 BD Phoenix PMIC/ID-94 25
448619 BD Phoenix PMIC/ID-90 25
448620 BD Phoenix NMIC/ID-415 25
448785 BD Phoenix SMIC/ID-11 25
448794 BD Phoenix NMIC/ID-402 25
448796 BD Phoenix PMIC/ID-88 25
448805 BD Phoenix UNMIC/ID-409 25
448873 BD Phoenix UNMIC/ID-403 25
448878 BD Phoenix NMIC/ID-408 25
449012 BD Phoenix NMIC/ID-418 25
449026 BD Phoenix NMIC/ID-503 25
449027 BD Phoenix NMIC/ID-504 25
449045 BD Phoenix NMIC/ID-433 25

BD Phoenix susceptibility panels
Catalogue no. Description Quantity (shelf pack)
448420 BD Phoenix Emerge PMIC-84 25
448439 BD Phoenix PMIC-90 25
448446 BD Phoenix UNMIC-416 25
448798 BD Phoenix PMIC-88 25
448804 BD Phoenix UNMIC-409 25
448874 BD Phoenix NMIC-402 25
448876 BD Phoenix UNMIC-403 25
448877 BD Phoenix NMIC-408 25
449001 BD Phoenix Emerge NMIC-417 25
449009 BD Phoenix Emerge PMIC-96 25
449023 BD Phoenix NMIC-500 25
449025 BD Phoenix Emerge NMIC-502 25
449056 BD Phoenix Emerge NMIC-505 25
449727 BD Phoenix Emerge NMIC 474 25
449728 BD Phoenix Emerge NMIC 475 25

Please note, not all products, services or features of products and services may be available in your local area. Please check with your local BD representative.

CE

*Depending on BD Phoenix panel type and organism identification.

References
  1. Junkins A, et al. Comparison of BD Phoenix AP Workflow with Vitek 2. J. Clin. Microbiol. 2010. 48 (5): 1929-1931. – Study was a supported grant from BD Diagnostic Systems

BD-38368

Go to top