BD Preset Eclipse Arterial Blood Collection Syringes

BD Preset™ Arterial Blood Collection Syringes Automatic Fill

BD Critical Care Collection Syringes are available with the BD Eclipse safety-engineered needle to minimise the chances of a needlestick injury to the the healthcare worker. The safety shield is integrated and is not an accessory to the needle. The needle bevel and safety shield are in alignment, ensuring no extra manipulation. The single-handed technique ensures no change in the collection technique and the double-locking mechanism is both visually and audibly confirmed for the healthcare worker.

High-quality results

Diagnostic accuracy

Safety

Safety

Handling and compatibility

Good critical care test results depend on the quality and integrity of blood gas samples; quality samples depend on blood gas syringes designed to minimise preanalytical variables.1

The BD Arterial Blood Collection Syringes are spray-coated with calcium-balanced Lithium heparin enabling easy dissolution to minimise clotting and dilution errors without compromising analyte measurements;

  • anticoagulates the sample after mixing2
  • meets the IFCC guidelines for heparin concentration in blood for dry heparin plastic syringes3

BD Preset Eclipse Arterial Blood Collection Syringe has been validated, and demonstrated stability for the following critical care analytes2:

  • Blood gases: pH, pCO2, pO2
  • Electrolytes: ionised calcium (iCa), sodium (Na), potassium (K), chloride (Cl)
  • Metabolites: glucose (GLU) and lactate (LACT)
  • Hemoglobin (Hb) and hematocrit (Hct)
  • Blood urea nitrogen (BUN) and creatinine (CREA)

BD Preset Eclipse is designed to preserve sample integrity, while protecting healthcare workers from needle stick injuries.

Reduce needlestick injuries with thumb pad for single step safety activation and audible lock confirmation.

BD Preset Eclipse Arterial Blood Collection Syringes Self-aspirated Fill

Cat. No.

Syringe volume (mL)

Recommended fill volume (mL)

Units of heparin* (IU per syringe / per mL of blood**)

Gauge

Needle length

Connection

Tip Cap

Case / Qty

364390

3.0

1.6

80 / 50

22 G (0.7 mm) BD Eclipse

1” (25 mm)

BD Luer-Lok

BD Hemogard

100

364389

3.0

1.6

80 / 50

22 G (0.7 mm) BD Eclipse

1.25” (32 mm)

BD Luer-Lok

BD Hemogard

100

364391

3.0

1.6

80 / 50

23 G (0.6 mm) BD Eclipse

1” (25 mm)

BD Luer-Lok

BD Hemogard

100

364393

3.0

1.6

80 / 50

25 G (0.5 mm) BD Eclipse

5/8" (16 mm)

BD Luer-Lok

BD Hemogard

100

* Spray-dried, calcium-balanced lithium heparin
** At recommended fill volume

BD Preset Arterial Blood Collection Syringes Self-aspirated Fill

Cat. No.

Syringe volume (mL)

Recommended fill volume (mL)

Units of heparin* (IU per syringe / per mL of blood**)

Gauge

Needle length

Connection

Tip Cap

Case / Qty

364416

1.0

0.6

30 / 50

-

-

Slip tip

Conventional

100

364316

3.0

1.6

80 / 50

-

-

BD Luer-Lok™

BD Hemogard

100

364413

1.0

0.6

30 / 50

23 G (0.6 mm)

1” (25 mm)

Slip tip

Conventional

100

364415

1.0

0.6

30 / 50

25 G (0.5 mm)

5/8” (16 mm)

Slip tip

Conventional

100

364314

3.0

1.6

80 / 50

22 G (0.7 mm)

1” (25 mm)

BD Luer-Lok™

Conventional

100

364327

3.0 1.6 80 / 50 23 G (0.6 mm) 1” (25 mm) BD Luer-Lok™ BD Hemogard 100

Please note, not all products, services or features of products and services may be available in your local area. Please check with your local BD representative.

  CE applies to the following products: 364416 & 364316

  All other products listed applies to CE 2797

References
  1. Pramod et al. Interpretation of arterial blood gas. Indian J Critical Care Medicine. June 2010.
  2. Data on file. Franklin Lakes, NJ: Becton, Dickinson and Company.
  3. Burnett RW, Covington AK, Fogh-Andersen N, et al. International Federation of Clinical Chemistry (IFCC). Scientific Division. Committee on pH, Blood Gases and Electrolytes. Approved IFCC recommendations on whole blood sampling, transport and storage for simultaneous determination of pH, blood gases and electrolytes. Eur J Clin Chem Clin Biochem. 1995;33:247-253.

BD-23618