Bard® Mesh

Monofilament polypropylene mesh for use in ventral or inguinal hernia repair.

Contact Us
Bard Mesh
Loading
Overview

The Gold Standard, Monofilament, Polypropylene Mesh

With more than 50 years of clinical experience, Bard® Mesh is the Gold Standard product to be used in a "tension-free" hernia repair technique. Bard® Mesh reinforces the weakened area, allowing for tissue ingrowth and resiliency. Bard® Mesh can be tailored preoperatively and customized to any unique situation.

true

Features and Benefits

  • More than 50 years of clinical experience
  • Can be tailored and trimmed to address surgeon needs
  • Available in six convenient sizes
  • Optional precut shapes provide opening for the spermatic cord, and the rounded edges accommodate to the anatomy of the inguinal canal
  • Well tolerated by the body1
  • Monofilament fibers are less prone to harbor bacteria than multifilament fibers1

Related Products

EIFUs
Resources
References

Please note, not all products, services or features of products and services may be available in your local area. Please check with your local BD representative.

Indications

Bard® Mesh is indicated for the repair of ventral, incisional, and inguinal hernias.

Contraindications

    1. Do not use this mesh in infants, children, or pregnant women, whereby future growth may be compromised by use of such mesh material.
    2. The use of this mesh has not been studied in breastfeeding or pregnant women.
    3. Do not use this mesh for the reconstruction of cardiovascular defects.
    4. Literature reports there may be a possibility for adhesion formation when the polypropylene is placed in direct contact with the bowel or viscera.

    Warnings.

    1. The use of any permanent mesh or patch in a contaminated or infected wound could lead to fistula formation and/or extrusion of the mesh.
    2. If an infection develops, treat the infection aggressively. Consideration should be given regarding the need to remove the mesh. An unresolved infection may require removal of the mesh.
    3. If unused mesh has been in contact with instruments or supplies used on a patient or contaminated with body fluids, discard with care to prevent risk of transmission of viral infections.
    4. To prevent recurrences when repairing hernias, the mesh should be sized with appropriate overlap for the size and location of the defect, taking into consideration any additional clinical factors applicable to the patient. Careful attention to mesh fixation placement and spacing will help prevent excessive tension or gap formation between the mesh and fascial tissue.
    5. The mesh is supplied sterile. Inspect the packaging to be sure it is intact and undamaged prior to use.
    6. This mesh has been designed for single use only. Reuse, reprocessing, resterilization or repackaging may compromise the structural integrity and/or essential material and design characteristics that are critical to the overall performance of the mesh and may lead to mesh failure which may result in injury to the patient. Reuse, reprocessing, resterilization or repackaging may also create a risk of contamination of the mesh and/or cause patient infection or cross infection, including, but not limited to, the transmission of infectious diseases from one patient to another. Contamination of the mesh may lead to injury, illness or death of the patient or end user.
    7. To avoid injury, careful attention is required if fixating the mesh in the presence of nerves, vessels or the spermatic cord. Fastener penetration into underlying tissue containing nerves or blood vessels may result in the need for medical/surgical intervention, cause serious injury or permanent impairment to a body structure.
    8. This mesh is not for the use of repair of pelvic organ prolapse via transvaginal approach.
    9. This mesh is not for the use of treatment of stress urinary incontinence.

    Precautions.

    1. Please read all instructions prior to use.
    2. Only physicians qualified in the appropriate surgical techniques should use this mesh.

    Adverse Reactions.

    Possible complications may include but are not limited to, seroma, adhesions, hematomas, pain, infection, inflammation, extrusion, erosion, migration, fistula formation, allergic reaction, and recurrence of the hernia or soft tissue defect. Please consult package insert for more detailed safety information and instructions for use.

    References
    1. Amid, Shulman, Lichtenstein. “Selecting Synthetic Mesh for the Repair of Groin Hernia.” Postgraduate General Surgery. 1992:4:150-155.

    BD- 51743

    true
    Bard® Mesh BD Bard® mesh ,
    • More than 50 years of clinical experience
    ,,
    • Can be tailored and trimmed to address surgeon needs
    ,,
    • Available in six convenient sizes
    ,,
    • Optional precut shapes provide opening for the spermatic cord, and the rounded edges accommodate to the anatomy of the inguinal canal
    ,,
    • Well tolerated by the body1
    ,,
    • Monofilament fibers are less prone to harbor bacteria than multifilament fibers1
    /content/dam/bd-assets/bd-com/en-us/logos/bd/header-bd-logo.svg

    Monofilament polypropylene mesh for use in ventral or inguinal hernia repair.

    2477-0007 BD Alaris™ LVP BLD180M 15D SS Alaris™ Pump Module set Non-Vented Blood Set 180 Micron Filter Roller, 2 Slide Clamp(s) 1 SmartSite™ needle-free valve(s) 65" (below pumping segment) from 2-piece Male Luer Lock. Not Made with DEHP. 15 Drop L: 121 in L: 308 cm PV: 33 mL Fluid Path Sterile 2466-0007 BD Alaris™ LVP SS BAG 20D LOW SORB Alaris™ Pump Module Set Non-Vented SmartSite™ bag access Low Sorbing (PE Lined) Roller Clamp(s) Spin Male Luer Lock. DEHP is not part of the material formulation. 20 Drop L: 87 in L: 220 cm PV: 21 mL Fluid Path Sterile 2465-0007 BD Alaris™ LVP SS BAG 20D LOW SORB SS 0.2M Non-vented needle-free valve bag access port low sorbing 0.2 micron filter (1.72 sq. in low protein binding) roller, pinch clamp(s) 1 SmartSite™ needle-free valve(s) 6" (below pumping segment) from 2-piece male luer lock. Not made with DEHP. 20 drop L: 116 in L: 294 cm PV: 27 mL fluid path sterile. 24600-0007 BD Alaris™ LVP 20D LOW SORB 3SS CV BD Alaris™ Pump Module Set Low Sorbing (PE Lined) Back Check Valve Roller Clamp(s) 3 SmartSite™ Y-site(s) 6", 66", 88" (1 above pumping segment and 2 below) from 2-piece Male Luer Lock. DEHP is not part of the material formulation. 20 Drop L: 120 in L: 304 cm PV: 25 mL Fluid Path Sterile 2452-0007 BD Alaris™ LVP 10D 3SS 2CV BD Alaris™ Pump Module set 2 Back Check Valves Roller Clamp(s) 3 SmartSite™ Y-site(s) 6", 42", 92" (1 above pumping segment and 2 below) from 2-piece Male Luer Lock. DEHP is not part of the material formulation. 10 Drop L: 111 in L: 282 cm PV: 25mL Fluid Path Sterile. 2441-0007 BD Alaris™ LVP BUR 60D SMBORE 3SS Alaris™ Pump Module set 150mL Burette (SmartSite™) Smallbore Roller, Slide Clamp(s) 3 SmartSite™ needle-free valve(s) 7", 48", 88" (1 above pumping segment and 2 below) from 2-piece Male Luer Lock. Not Made with DEHP. 60 Drop L: 130 in L: 330 cm PV: 20 mL Fluid Path Sterile 2432-0007 BD Alaris™ LVP 20D 3SS 0.2M CV Alaris™ Pump Module set Check Valve 0.2 Micron Filter (1.72 sq. in Low Protein Binding) Roller, Slide Clamp(s) 3 SmartSite™ needle-free valve(s) 6", 18", 86" (1 above pumping segment and 2 below) from 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L: 117 in L: 297 cm PV: 28 mL Fluid Path Sterile 24302-0004 BD Alaris™ LVP 20D 2SS 15M Alaris™ Pump Module Set Roller, 15 Micron Filter (Drip Chamber), Slide Clamp(s) 2 SmartSite™ Y-site(s) 6" and 87" (1 above pumping segment and 1 below) from 2-piece Male Luer Lock. 20 Drop L: 292 cm PV: 24 mL Fluid Path Sterile 2426-0500 BD Alaris™ LVP 20D DEHP 3SS CV Alaris™ Pump Module set Check Valve Roller, Slide Clamp(s) 3 SmartSite™ needle-free valve(s) 6", 74", 90" (1 above pumping segment and 2 below) from 2-piece Male Luer Lock. 20 Drop L: 126 in L: 321 cm PV: 26 mL Fluid Path Sterile 2426-0007 BD Alaris™ LVP 20D 3SS CV Alaris™ Pump Module set Check Valve Roller, Slide Clamp(s) 3 SmartSite™ needle-free valve(s) 6", 74", 90" (1 above pumping segment and 2 below) from 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L: 126 in L: 320 cm PV: 26 mL Fluid Path Sterile 2420-0500 BD Alaris™ LVP 20D DEHP 2SS CV Alaris™ Pump Module set Check Valve Roller Clamp(s) 2 SmartSite™ needle-free valve(s) 6", 81" (1 above pumping segment and 1 below) from 2-piece Male Luer Lock. 20 Drop L: 117 in L: 297 cm PV: 25 mL Fluid Path Sterile 2420-0007 BD Alaris™ LVP 20D 2SS CV Alaris™ Pump Module set Check Valve Roller Clamp(s) 2 SmartSite™ needle-free valve(s) 6", 81" (1 above pumping segment and 1 below) from 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L: 117 in L: 297 cm PV: 25 mL Fluid Path Sterile 2403-0007 BD Alaris™ LVP HALF SS Alaris™ Pump Module Set Half Set Roller Clamp(s) 1 SmartSite™ Y-site(s) 6" (below pumping segment) from 2-piece Male Luer Lock. DEHP is not part of the material formulation. L: 87 in L: 220 cm PV: 13 mL Fluid Path Sterile 24010-0007t BD Alaris™ LVP 20D 3SS TEX CV BD Alaris™ Pump Module set Check valve roller, pinch clamp(s) 3 SmartSite™ needle-free valve(s) 96", 74", 6" from Texium™ closed male luer. Not made with DEHP. 20 drop L: 126 in L: 321 cm PV: 26 mL fluid path sterile. 2278-0500 BD Alaris™ LVP BLD200M 20D DEHP SMBORE Alaris™ Pump Module Set Non-Vented Blood Set 200 Micron Filter Roller Clamp(s) 2-piece Male Luer Lock. 20 Drop L: 121 in L: 307 cm PV: 33 mL Fluid Path Sterile 2260-0500 BD Alaris™ LVP 20D LOW SORB Alaris™ Pump Module set Low Sorbing Roller Clamp(s) 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L: 113 in L: 286 cm PV: 23 mL Fluid Path Sterile 2206-0007 BD Alaris™ LVP 20D YELLOW MICROBORE Alaris™ Pump Module set Microbore yellow striped roller clamp(s) 2-piece male luer lock. Not made with DEHP. 20 drop L: 98 in L: 248 cm PV: 13 mL fluid path sterile. 2204-0007 BD Alaris™ LVP 20D Alaris™ Pump Module set Roller Clamp(s) 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L: 47 in L: 119 cm PV: 14 mL Fluid Path Sterile 2202-0007 BD Alaris™ LVP 20D 1.2M Alaris™ Pump Module Set 1.2 Micron Filter (1.72 sq. in Low Protein Binding) Roller, Pinch Clamp(s) 2-piece Male Luer Lock. DEHP is not part of the material formulation. 20 Drop L: 122 in L: 309 cm PV: 27 mL Fluid Path Sterile 11532269 BD Alaris™ LVP 20D LOW SORB 2SS 0.2M CV Alaris™ Pump Module set Low Sorbing Check Valve 0.2 Micron Filter (1.72 sq. in Low Protein Binding) Roller, Pinch Clamp(s) 2 SmartSite™ needle-free valve(s) 6 11171447 BD Alaris™ LVP 20D 3SS 2CV Alaris™ Pump Module Set Back Check Valve Roller, Slide, 2 Pinch Clamp(s) 3-way Stopcock (OFF Indicator) 3 Port Manifold (3 One Way Valves) 2 Female Luers 3 Male Luers 5 SmartSite™ Y-site(s) 6", 21", 39", 103", 125" (1 above pumping segment and 4 below) from 2-piece Male Luer Lock. 20 Drop L: 159 in L: 403 cm PV: 31 mL Fluid Path Sterile 10942011 BD Alaris™ LVP 20D Alaris™ Pump Module set Roller Clamp(s) 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L: 109 in L: 277 cm PV: 23 mL Fluid Path Sterile 10863358 BD Alaris™ LVP 20D DEHP 15M Alaris™ Pump Module Set 15 Micron Filter (Drip Chamber) Roller Clamp(s) 2-piece Male Luer Lock. 20 Drop L: 117 in L: 296 cm PV: 25 mL Fluid Path Sterile 10561554 BD Alaris™ LVP 20D DEHP 3SS 15M CV Alaris™ Pump Module Set Back Check Valve 15 Micron Filter (Drip Chamber) Roller, Slide Clamp(s) 3 SmartSite™ Y-site(s) 6", 74", 96" (1 above pumping segment and 2 below) from 2-piece Male Luer Lock. 20 Drop L: 126 in L: 321 cm PV: 26 mL Fluid Path Sterile 10015861a BD Alaris™ LVP SS BAG 20D LOW SORB 3SS CV Alaris™ Pump Module set Non-vented needle-free valve bag access port low sorbing check valve roller, pinch clamp(s) 3 SmartSite™ needle-free valve(s) 6", 74", 96" (1 above pumping segment and 2 below) from 2-piece male luer lock. Not made with DEHP. 20 drop L: 127 in L: 323 cm PV: 25 mL fluid path sterile. 10015414 BD Alaris™ LVP BLD180M 15D DEHP Non-vented blood set 180 micron filter roller, 2 slide clamp(s) 2-piece male luer lock. 15 drop L: 126 in L: 318 cm PV: 37 mL fluid path sterile. 10015012 BD Alaris™ LVP BUR 20D LOW SORB SMBORE SS 0.2M Alaris™ Pump Module Set 150mL Burette (SmartSite™) Smallbore Tubing Segments Low Sorbing (PE Lined) Segments 0.2 Micron Filter (1.72 sq. in Low Protein Binding) 2 Roller, 2 Pinch Clamp(s) 1 SmartSite™ Y-site(s) 6" (below pumping segment) from 2-piece Male Luer Lock. DEHP is not part of the material formulation. 20 Drop L: 125 in L: 317 cm PV: 26 mL Fluid Path Sterile 10013361t BD Alaris™ LVP SS BAG 20D 2SS TEX CV Non-vented needle-free valve bag access port check valve roller clamp(s) 2 SmartSite™ needle-free valve(s) 6", 87" (1 above pumping segment and 1 below) from bonded Texium™ closed male luer. Not made with DEHP. 20 drop L: 118 in L: 298 cm PV: 25 mL fluid path sterile. 10013186 BD Alaris™ LVP 60D DEHP 3SS CV Back Check Valve 2 Roller Clamp(s) 3 SmartSite™ Y-site(s) 6", 36", 87" (1 above pumping segment and 2 below) from 2-piece Male Luer Lock. 60 Drop L: 117 in L: 297 cm PV: 25 mL Fluid Path Sterile 10013072 BD Alaris™ LVP 20D LOW SORB 2SS CV Alaris™ Pump Module Set Low Sorbing (PE Lined) Back Check Valve Roller Clamp(s) 2 SmartSite™ Y-site(s) 6", 82" (1 above pumping segment and 1 below) from 2-piece Male Luer Lock. DEHP is not part of the material formulation. 20 Drop L: 103 in L: 262 cm PV: 22 mL Fluid Path Sterile 10010483 BD Alaris™ LVP VSA SMBORE BD Alaris™ Pump Module set Syringe Adapter Smallbore Slide Clamp(s) 2-piece Male Luer Lock. Not Made with DEHP. L: 82 in L: 208 cm PV: 4 mL Fluid Path Sterile 10010454 BD Alaris™ LVP 20D LOW SORB SS 0.2M Low sorbing 0.2 micron filter (1.72 sq. in low protein binding) roller, pinch clamp(s) 1 SmartSite™ needle-free valve(s) (below pumping segment) 6" from 2-piece male luer lock. Not made with DEHP. 20 drop L: 115 in L: 291 cm PV: 26 mL fluid path sterile. 10010453 BD Alaris™ LVP 20D LOW SORB SS 1.2M Alaris™ Pump Module set Low Sorbing 1.2 Micron Filter (1.72 sq. in Low Protein Binding) Roller, Pinch Clamp(s) 1 SmartSite™ needle-free valve(s) 6" (below pumping segment) from 2-piece Male Luer Lock. Not Made with DEHP. 20 Drop L: 115 in L: 291 cm PV: 26 mL Fluid Path Sterile