Ultraverse™ 014 PTA Dilatation Catheters

Angioplasty – Small Vessel Solutions 0.014”

Contact Us
BDPI_Ultraverse_PF10068_Product-Image
Loading
Overview
  • The Ultraverse® 014 PTA Balloon Catheter consists of a flexible, over the-wire (OTW ) catheter shaft with a semi-compliant balloon fixed at the distal end.
  •  For all balloon lengths, radiopaque markers delineate the working length of the balloon and aid in balloon placement. 
  • Balloon length of 100 mm and greater come with two radiopaque markers.
  • The catheters include an atraumatic tip to facilitate advancement of the catheter to and through the stenosis.
true
Indication

Ultraverse® 014 PTA Dilatation Catheters are recommended for use in percutaneous transluminal angioplasty (PTA) of the renal, popliteal, tibial, femoral, and peroneal arteries.

Features & Benefits

GeoAlign® Marking System

The GeoAlign® Marking System is a non-radiopaque ruler on the catheter shaft measured from the distal tip. It is a tool to externally measure the intravascular advancement and/or retraction of the catheter. This can provide an intravascular reference regarding the location of the distal tip of the catheter or an approximate intravascular length measurement between two points. The GeoAlign® Marking System may also facilitate geographic alignment of an adjunctive therapy that includes the same GeoAlign® Marking System.

Products & Accessories
RELATED PRODUCTS NOT AVAILABLE
EIFUs
Resources

References

The GeoAlign® Marking System is not a replacement for fluoroscopy. When the catheter is exposed to the vascular system, the location of the balloon should be confirmed while under high quality fluoroscopic observation.

Please consult Instructions for Use for product indications for use, contraindications, warnings, precautions, complications, adverse events and detailed safety information.

true
true
Ultraverse™ 014 PTA Dilatation Catheters BD Ultraverse™ 014 PTA Dilatation Catheters /content/dam/bd-assets/bd-com/en-us/logos/bd/header-bd-logo.svg

Angioplasty – Small Vessel Solutions 0.014”

PTA, Percutaneous Transluminal Angioplasty, Ultra-Cross, hydrophilic coating, Checker flex, small vessel PTA Balloon