true

Atlas™ Gold PTA Dilatation Catheters

Angioplasty – Large Diameter Vessel Solutions .035”

Contact Us
BD_BARD_INTERVENTIONAL_PI_PF10008-ATLAS-GOLD
Loading
Overview
  • Large balloon diameters up to 26mm
  • Ultra non-compliant technology offers virtually no growth past stated diameter*
  • Tapered tip to facilitate trackability
  • Delivers maximum force to areas of most resistance (up to 18 ATM)
  • Short shoulders designed to minimize vessel straightening and allow for high pressure post-dilation at stent edges
References

*Bench testing (n=45; 15 samples each of 12mmx2mmx80cm, 20mmx4mmx80cm, 26mmx4mmx120cm) may not be indicative of clinical performance. Demonstrated less than 2% mean compliance between nominal pressure and rated burst pressure. Data on file, Bard Peripheral Vascular, Inc. Tempe, AZ. Different test methods may yield different results.

Please consult Instructions for Use for product indications for use, contraindications, warnings, precautions, complications, adverse events and detailed safety information.

true

BD-23444

References

*Bench testing (n=45; 15 samples each of 12mmx2mmx80cm, 20mmx4mmx80cm, 26mmx4mmx120cm) may not be indicative of clinical performance. Demonstrated less than 2% mean compliance between nominal pressure and rated burst pressure. Data on file, Bard Peripheral Vascular, Inc. Tempe, AZ. Different test methods may yield different results.

Please consult Instructions for Use for product indications for use, contraindications, warnings, precautions, complications, adverse events and detailed safety information.

true
EIFUs
Resources
References

*Bench testing (n=45; 15 samples each of 12mmx2mmx80cm, 20mmx4mmx80cm, 26mmx4mmx120cm) may not be indicative of clinical performance. Demonstrated less than 2% mean compliance between nominal pressure and rated burst pressure. Data on file, Bard Peripheral Vascular, Inc. Tempe, AZ. Different test methods may yield different results.

Please consult Instructions for Use for product indications for use, contraindications, warnings, precautions, complications, adverse events and detailed safety information.

true
Frequently Asked Questions
false
true
Atlas™ Gold PTA Dilatation Catheters BD Atlas™ GOLD PTA Dilatation Catheters /content/dam/bd-assets/bd-com/en-us/logos/bd/header-bd-logo.svg

Angioplasty – Large Diameter Vessel Solutions .035”

atg80264 Atlas™ Gold PTA Dilatation Catheter - 26 mm x 4 cm Balloon with a Rated Burst Pressure of 12 ATM on 80 cm Shaft with 12F Sheath atg80262 Atlas™ Gold PTA Dilatation Catheter - 26 mm x 2 cm Balloon with a Rated Burst Pressure of 12 ATM on 80 cm Shaft with 12F Sheath atg80244 Atlas™ Gold PTA Dilatation Catheter - 24 mm x 4 cm Balloon with a Rated Burst Pressure of 14 ATM on 80 cm Shaft with 10F Sheath atg80242 Atlas™ Gold PTA Dilatation Catheter - 24 mm x 2 cm Balloon with a Rated Burst Pressure of 14 ATM on 80 cm Shaft with 10F Sheath atg80224 Atlas™ Gold PTA Dilatation Catheter - 22 mm x 4 cm Balloon with a Rated Burst Pressure of 14 ATM on 80 cm Shaft with 10F Sheath atg80222 Atlas™ Gold PTA Dilatation Catheter - 22 mm x 2 cm Balloon with a Rated Burst Pressure of 14 ATM on 80 cm Shaft with 10F Sheath
Large Diameter PTA Balloon, Shorter PTA Balloon shoulders, Non-complaint PTA Balloon, PTA, Curved Vessel Lesions, Multiple lesion specific pressures