StatLock™ IV Select Stabilization Device

The StatLock™ IV Select Stabilization Device is universally compatible with most peripheral IV catheters.

Contact Us
Statlock Peripheral IV Select Hero
Loading
Overview

Highlights

  • Universally compatible with most peripheral IV catheters.
  • Entry angle of retainer is designed to prevent catheter kinking, which could  lead to occlusion.
  • Includes patented luer-lock extension set – just snap the retainer over the custom-crafted luer, peel and place.
  • Breathable anchor pad made from non-absorbent tricot polyester.
  • Sterile, DEHP-free and Latex-free.
true
Features and Benefits

The StatLock™ IV Select Stabilization Device is universally compatible with most periphial IV catheters via securement to the BD provided extension set. The snap fits onto the extension set behind the luer. 

StatLock™ Stabilization Devices are a more effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies.

Products & Accessories
RELATED PRODUCTS NOT AVAILABLE
References
false
EIFUs
Resources
Frequently Asked Questions

Nearly.The StatLock stabilization device is contraindicated in patients with known allergies to adhesives or tapes.

While the StatLock stabilization device is probably appropriate for more than 99% of your patients; some people have skin that simply will not accept an adhesive-based product – their skin is too flaky, too greasy, or too diaphoretic. Use clinical judgment. Just know that where you can use StatLock stabilization device, your clinical and cost outcomes will be dramatically improved.

You do need to extend your insertion site alcohol prep or chlorhexidine prep widely to both sides to cover the securement site. This is a necessary step to cleanse the skin before the StatLock stabilization device application.

BD recommends the use of the skin prep pad included with the StatLock stabilization device. The skin prep provides an acrylic layer that protects the skin and enhances adherence of the anchor pad. Performing both of these steps will maximize product performance.

When you use the skin prep you'll need to allow it to dry for 10 to 15 seconds and make certain it is dry, meaning smooth to the touch – not tacky. Use your clinical judgment based on assessment of the patient's skin. Just remember, when skin prep is not used the StatLock stabilization devices may prematurely lift.

Yes.

  • Always orient the push-tab straight up.
  • Always connect the StatLock stabilization retainer device to the PIV before placing the StatLock stabilization device onto skin.
  • The blue StatLock stabilization device retainer clip is like an upside-down "V". Therefore, do not inadvertently squeeze it closed by compressing both sides. Instead, just hold one side and snap it over the hub of the catheter.

You can use them to:

  • Stabilize the catheter while prepping and securing with the StatLock stabilization device by applying the foam strips over the catheter hub
  • Fashion a J-loop with the IV tubing
  • Form a cushion under your luer lock spin nut
  • For extension sets without luer locks, wrap them around the catheter and the extension set connection for added security
  • Reinforce the StatLock stabilization devices. They are sterile, tape is not.

If you had a tape-secured PIV, then you would have to remove the tape to change the tubing.

StatLock IV Ultra stabilization device

With the StatLock IV Ultra stabilization device you can keep the stabilization device in place while you change tubing. Simply steady the retainer with the thumb and index finger of one hand while unscrewing the extension set. Remove the set. Then, while continuing to brace the retainer, press-fit and screw in your replacement extension set.

StatLock IV Select stabilization device

For StatLock IV Select stabilization device, you will need to replace the StatLock stabilization devices when you remove and replace the tubing – just as you would with tape securement; but this is a rare event offset by StatLock stabilization device advantages.

<p>Nearly.The StatLock stabilization device is contraindicated in patients with known allergies to adhesives or tapes.</p> <p>While the StatLock stabilization device is probably appropriate for more than 99% of your patients; some people have skin that simply will not accept an adhesive-based product – their skin is too flaky, too greasy, or too diaphoretic. Use clinical judgment. Just know that where you can use StatLock stabilization device, your clinical and cost outcomes will be dramatically improved.</p>

<p>You do need to extend your insertion site alcohol prep or chlorhexidine prep widely to both sides to cover the securement site. This is a necessary step to cleanse the skin before the StatLock stabilization device application.</p> <p>BD recommends the use of the skin prep pad included with the StatLock stabilization device. The skin prep provides an acrylic layer that protects the skin and enhances adherence of the anchor pad. Performing both of these steps will maximize product performance.</p> <p>When you use the skin prep you'll need to allow it to dry for 10 to 15 seconds and make certain it is dry, meaning smooth to the touch – not tacky. Use your clinical judgment based on assessment of the patient's skin. Just remember, when skin prep is not used the StatLock stabilization devices may prematurely lift.</p>

<p>Yes.</p> <li>Always orient the push-tab straight up.</li> <li>Always connect the StatLock stabilization retainer device to the PIV before placing the StatLock stabilization device onto skin.</li> <li>The blue StatLock stabilization device retainer clip is like an upside-down "V". Therefore, do not inadvertently squeeze it closed by compressing both sides. Instead, just hold one side and snap it over the hub of the catheter.</li>

<p>You can use them to:</p> <li>Stabilize the catheter while prepping and securing with the StatLock stabilization device by applying the foam strips over the catheter hub</li> <li>Fashion a J-loop with the IV tubing</li> <li>Form a cushion under your luer lock spin nut</li> <li>For extension sets without luer locks, wrap them around the catheter and the extension set connection for added security</li> <li>Reinforce the StatLock stabilization devices. They are sterile, tape is not.</li>

<p>If you had a tape-secured PIV, then you would have to remove the tape to change the tubing.</p> <p><strong>StatLock IV Ultra stabilization device</strong></p> <p>With the StatLock IV Ultra stabilization device you can keep the stabilization device in place while you change tubing. Simply steady the retainer with the thumb and index finger of one hand while unscrewing the extension set. Remove the set. Then, while continuing to brace the retainer, press-fit and screw in your replacement extension set.</p> <p><strong>StatLock IV Select stabilization device</strong></p> <p>For StatLock IV Select stabilization device, you will need to replace the StatLock stabilization devices when you remove and replace the tubing – just as you would with tape securement; but this is a rare event offset by StatLock stabilization device advantages.</p>

true

References

Please note, not all products, services or features of products and services may be available in your local area. Please check with your local BD representative.

Please consult product labels, IFU, and package inserts for any indications, contraindications, hazards, warnings, cautions, and instructions for use.

BD-113923

true
StatLock™ IV Select Stabilization Device BD StatLock™ IV Select Stabilization Device ,

The StatLock™ IV Select Stabilization Device is universally compatible with most periphial IV catheters via securement to the BD provided extension set. The snap fits onto the extension set behind the luer. 

,,

StatLock™ Stabilization Devices are a more effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies.

/content/dam/bd-assets/bd-com/en-us/logos/bd/header-bd-logo.svg

The StatLock™ IV Select Stabilization Device is universally compatible with most peripheral IV catheters.

369741 13x75 mm 2.4 mL BD Vacutainer® glass plasma ESR tube 369714 Sodium citrate tube, .105 M/3.2% 368824 13x75 mm 2.4 mL BD Vacutainer® glass plasma ESR tube 368774 BD Vacutainer® Rapid Serum Tube 368661 BD Vacutainer® EDTA Tubes 368660 BD Vacutainer® Serum Tubes 368589 BD Vacutainer® EDTA Tubes 368587 BD Vacutainer® Fluoride Tubes 368381 BD Vacutainer® Specialty Tubes 368380 BD Vacutainer® Specialty Tubes 368056 BD Vacutainer® PST™ Tubes 367989 BD Vacutainer® SST™ Tubes 367988 BD Vacutainer® SST™ Tubes 367987 BD Vacutainer® SST™ Tubes 367986 BD Vacutainer® SST™ Tubes 367985 BD Vacutainer® SST™ Tubes 367983 BD Vacutainer® SST™ Tubes 367981 BD Vacutainer® SST™ Tubes 367977 BD Vacutainer® SST™ Tubes 367964 BD Vacutainer® PST™ Tubes 367963 BD Vacutainer® PST™ Tubes 367962 BD Vacutainer® PST™ Tubes 367961 BD Vacutainer® PST™ Tubes 367960 BD Vacutainer® PST™ Tubes 367947 CTAD tube 367925 BD Vacutainer® Fluoride Tubes 367922 BD Vacutainer® Fluoride Tubes 367921 BD Vacutainer® Fluoride Tubes 367899 BD Vacutainer® EDTA Tubes 367886 BD Vacutainer® Heparin Tubes 367884 BD Vacutainer® Heparin Tubes 367880 BD Vacutainer® Heparin Tubes 367878 BD Vacutainer® Heparin Tubes 367874 BD Vacutainer® Heparin Tubes 367871 BD Vacutainer® Heparin Tubes 367863 BD Vacutainer® EDTA Tubes 367862 BD Vacutainer® EDTA Tubes 367861 BD Vacutainer® EDTA Tubes 367856 BD Vacutainer® EDTA Tubes 367855 K2EDTA tube for lead testing 367844 BD Vacutainer® EDTA Tubes 367842 BD Vacutainer® EDTA Tubes 367841 BD Vacutainer® EDTA Tubes 13x75 mm tube, 2 mL draw volume, K2EDTA 3.6 mg 367835 BD Vacutainer® EDTA Tubes 367820 BD Vacutainer® Serum Tubes 16x100 mm tube, 10 mL draw volume, clot activator, silicone coated 367815 BD Vacutainer® Serum Tubes 13x100 mm tube, 6 mL draw volume, clot activator, silicone coated 367814 BD Vacutainer® Serum Tubes 13x100 mm tube, 5 mL draw volume, clot activator, silicone coated 367812 BD Vacutainer® Serum Tubes 13x75 mm tube, 4 mL draw volume, clot activator, silicone coated 367729 BD Vacutainer® Fluoride Tubes 367671 BD Vacutainer® Heparin Tubes 367587 BD Vacutainer® Fluoride Tubes 367290 BD Vacutainer® Luer Adapter 367001 BD Vacutainer® Fluoride Tubes 366704 BD Vacutainer® Specialty Tubes 13x75 mm tube, 3 mL draw volume, no additive 366703 BD Vacutainer® Specialty Tubes 13x75 mm tube, 3 mL draw volume, no additive 366668 BD Vacutainer® Serum Tubes 13x75 mm tube, 3 mL draw volume, clot activator, silicone coated 366667 BD Vacutainer® Heparin Tubes 366664 BD Vacutainer® Heparin Tubes 13x75 mm tube, 2 mL draw volume, lithium heparin 37 USP units 366643 BD Vacutainer® EDTA Tubes 16x100 mm tube, 10 mL draw volume, K2EDTA 18mg 366480 BD Vacutainer® Heparin Tubes 366473 13x75 mm 3.0 mL BD Vacutainer® plastic P700 plasma tube. Lavender BD Hemogard™ closure. Paper label. K2 EDTA 5.4 mg and proprietary DPP-IV inhibitor that enables preservation of GLP 1. For Research Use Only. 366450 BD Vacutainer® EDTA Tubes 366430 BD Vacutainer® Serum Tubes 16x100 mm tube, 10 mL draw volume, silicone coated 366401 BD Vacutainer® Specialty Tubes 364960 BD Vacutainer® Specialty Tubes 364816 BD Vacutainer® Specialty Tubes 364606 BD Vacutainer® Specialty Tubes 363083 BD Vacutainer® Citrate Tubes 363080 BD Vacutainer® Citrate Tubes