BD Microtainer® Tubes are used to collect, transport and store blood specimens obtained through skin puncture. The tubes are applicable to the general population, but are particularly used on infants, small children, geriatric, and critical care patients from whom venous blood specimens are particularly difficult to obtain.

The cap colours correspond to those used in venous blood collection tubes to identify the tube additive. Fill lines on the tubes ensure correct fill volume and blood: additive ratio.

BD Microgard™ Closure

The special design of the BD Microgard™ safety closure substantially reduces blood splashing after the tubes has been opened.

true
Features and Benefits
Promotional Story
false
Specification

GTIN - Shelfpack

30382903659938

50

GTIN - Each

00382903659937

1

GTIN - Case

50382903659932

200

GTIN

GTIN - Shelfpack 30382903659938 50
GTIN - Each 00382903659937 1
GTIN - Case 50382903659932 200
Electronic Instructions for Use (eIFUs)
Resources
Frequently Asked Questions

BD microcollection Tubes are packaged 50/bag, 200/case.

<p>According to CLSI "Procedures and Devices for the Collection of Diagnostic Capillary Blood Specimens" (H4-A6 Vol. 28 #25 September 2008) draw order should be:</p> <ol> <li>EDTA tubes</li> <li>Other additive tubes</li> <li>Serum tubes</li> </ol>

The caps are HDPE (high density polyethylene) and the tubes are polypropylene.

Microtainer tubes are equipped with two different closure types. The external dimensions of tubes with the BD Microgard™ closure are 15.35-mm X 46-mm. Microtainer tubes with FloTop collector closures meaure 9.85-mm X 52.07-mm.

Microtainer tubes with gel should be spun at 6000-15000 relative centrifugal force (RCF) for 90 seconds and non-gel tubes at a minimum of 2000 RCF for 3 minutes.

BD Microtainer K2EDTA with Microgard™ closure (#365974) is certified for lead. The background amount of lead is less than 1 ng per tube.

There is enough K2EDTA to anticoagulate blood volume from 250-500 μL. The average amount of K2EDTA in the tube is 1.0-mg.

Specimens can be stored in Microtainer® EDTA tubes for up to four hours at room temperature prior to performing hematological determinations

The BD Microtainer serum seperator tubes are available with two different closure types. The tube with BD Microgard™ closure (#365967) has clot activator on the walls. The tube with an attachable Flo-Top collector (#365956) does not have a clot activator on the walls.

BD microcollection Tubes are packaged 50/bag, 200/case.

<p>According to CLSI "Procedures and Devices for the Collection of Diagnostic Capillary Blood Specimens" (H4-A6 Vol. 28 #25 September 2008) draw order should be:</p> <ol> <li>EDTA tubes</li> <li>Other additive tubes</li> <li>Serum tubes</li> </ol>

The caps are HDPE (high density polyethylene) and the tubes are polypropylene.

Microtainer tubes are equipped with two different closure types. The external dimensions of tubes with the BD Microgard™ closure are 15.35-mm X 46-mm. Microtainer tubes with FloTop collector closures meaure 9.85-mm X 52.07-mm.

Microtainer tubes with gel should be spun at 6000-15000 relative centrifugal force (RCF) for 90 seconds and non-gel tubes at a minimum of 2000 RCF for 3 minutes.

BD Microtainer K2EDTA with Microgard™ closure (#365974) is certified for lead. The background amount of lead is less than 1 ng per tube.

There is enough K2EDTA to anticoagulate blood volume from 250-500 μL. The average amount of K2EDTA in the tube is 1.0-mg.

Specimens can be stored in Microtainer® EDTA tubes for up to four hours at room temperature prior to performing hematological determinations

The BD Microtainer serum seperator tubes are available with two different closure types. The tube with BD Microgard™ closure (#365967) has clot activator on the walls. The tube with an attachable Flo-Top collector (#365956) does not have a clot activator on the walls.