true

Acumen IQ™ Plus Cuff

Continuous noninvasive blood pressure and advanced haemodynamic monitoring

Acumen IQ Plus cuff header
Loading
Overview

Advanced insights at your fingertips

Acumen IQ™ Plus Cuff provides beat-to-beat blood pressure and advanced haemodynamic monitoring noninvasively–ensuring continuous insights never come at the cost of unnecessary invasiveness. Unlock the power of predictive software that detects haemodynamic instability and enables you to drill down to the root cause—so you can prevent or treat hypotension.

Manage pressure and flow noninvasively

  • crossing arrows

    Continuous advanced haemodynamic parameters, including stroke volume (SV), stroke volume variation (SVV) and cardiac output (CO)

  • magnifying glass

    Beat-to-beat blood pressure with accuracy comparable to a radial arterial line

  • heart in hand

    Comprehensive insights into preload, afterload and contractility, helping you identify and treat the potential root cause of haemodynamic instability

  • heart star

    AI-guided predictive decision support from Acumen Hypotension Prediction Index™ (HPI™) Software

AIQ cuff asset 01

Why advanced monitoring matters

The Anesthesia Patient Safety Foundation has identified haemodynamic instability as a critical patient safety issue, emphasizing the need for proactive management to prevent harm.1 Advanced predictive monitoring goes beyond blood pressure, providing continuous insights into haemodynamic trends that can help clinicians detect instability, identify the potential root cause and intervene sooner.

Key Haemodynamic Parameters

Gain noninvasive access to advanced haemodynamic parameters

Arterial lines can be costly and are associated with complications. For patients who don’t need or can’t have an arterial line, Acumen IQ™ Plus Cuff provides noninvasive access to continuous advanced haemodynamic monitoring.

  • Hypotension Prediction Index™ (HPI™)
  • Systolic Slope (dP/dt)
  • Dynamic Arterial Elastance (Eadyn)
  • Stroke Volume (SV)
  • Stroke Volume Variation (SVV)
  • Mean Arterial Pressure (MAP)
  • Cardiac Output (CO)
  • Systemic Vascular Resistance (SVR)
  • Pulse Pressure Variation (PPV)
Predictive Software
Alta monitor HPI

Unlock the power of predictive care

Acumen IQ™ Plus Cuff unlocks Acumen Hypotension Prediction Index™ (HPI™) Software. Acumen HPI™ Software provides AI-guided, predictive decision support to help you drill down to the potential root cause of haemodynamic instability and intervene sooner.

Simplify clinical workflows

Keep pace with simplified setup

Acumen IQ™ Plus Cuff with Smart Pressure Controller offers a simpler, faster workflow that keeps you focused on patients.

Simplified setup

Setup in under 60 seconds, saving valuable time and accelerating access to patient monitoring 

Acumen IQ™ Cuff setup guide

Streamlined design

Compact design and longer cable offer flexibility during setup and patient positioning

Acumen IQ™ Cuff setup guide

Secure fit

Self-coiling cuff with an adjustable fastener naturally hugs the finger for a secure fit and decreases variability in application 

Acumen IQ™ Cuff setup guide

Embedded HRS

Integrated Heart Reference Software automatically accounts for differences in pressure due to height differences between the finger and the heart

References
  1. Scott MJ, APSF HIWG. Perioperative patients with hemodynamic instability: Consensus recommendations of the Anesthesia Patient Safety Foundation. Anesth Analg. 2024;138(4):713-724
true
Why Continuous?

Noninvasive beat-to-beat blood pressure monitoring

Acumen IQ™ Plus Cuff enables noninvasive beat-to-beat blood pressure monitoring—extending the benefits of continuous monitoring to a broader patient population.

map time graph

Reduce intraoperative hypotension with continuous insights1-3

Periods of intraoperative hypotension can be missed when a patient's blood pressure is only monitored with an intermittent oscillometric cuff.4

hypotension reduction graph

Continuous noninvasive monitoring from BD has been demonstrated to reduce hypotension by about 90% during noncardiac surgery.*1

*Demonstrated in a randomized controlled trial of noncardiac surgery patients and compared to intermittent monitoring with an oscillometric cuff. Hypotension defined as time-weighted average (TWA) MAP <65 mmHg for at least 1 min during surgery.

References
  1. Kouz K, Weidemann F, Naebian A, et al. Continuous finger-cuff versus intermittent oscillometric arterial pressure monitoring and hypotension during induction of anesthesia and noncardiac surgery: The DETECT randomized trial. Anesthesiology. 2023;139(3):298-308
  2. Chen G, Chung E, Meng L, et al. Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management. J Clin Monit Comput. 2012;26(2):133-140
  3. Meidert SA, Nold JS, Hornung R, et al. The impact of continuous non-invasive arterial blood pressure monitoring on blood pressure stability during general anesthesia in orthopedic patients. Eur J Anaesthesiol. 2017;34:716-722
  4. Kouz K, Wegge M, Flick M, et al. Continuous intra-arterial versus intermittent oscillometric arterial pressure monitoring and hypotension during induction of anaesthesia: The AWAKE randomised trial. Br J Anaesth. 2022;129(4):478-486
Related products

Detect haemodynamic instability

Acumen Hypotension Prediction Index™ (HPI™) Software

Unlock predictive decision support through an arterial line

Acumen IQ™ Sensor

Learn more

Reimagine the way you see haemodynamic monitoring

HemoSphere Alta™ Monitor

Learn more

Analyze retrospective haemodynamic insights

Acumen Analytics™ Software

Learn more

References
Resources
References

Let's have a conversation

Fill out our form to have one of our haemodynamics experts contact you

Acumen IQ™ Plus Finger Cuff
Continuous noninvasive blood pressure and advanced hemodynamic monitoring
true
true
Acumen IQ™ Plus Cuff /content/dam/bd-assets/na/advanced-patient-monitoring/web-published/aiq-cuff-page/acumeniq-plus-cuff-og.jpg BD Acumen IQ™ Plus Finger Cuff” Acumen IQ™

Simplified setup

,

Setup in under 60 seconds, saving valuable time and accelerating access to patient monitoring 

,

Streamlined design

,

Compact design and longer cable offer flexibility during setup and patient positioning

,

Secure fit

,

Self-coiling cuff with an adjustable fastener naturally hugs the finger for a secure fit and decreases variability in application 

,

Embedded HRS

,

Integrated Heart Reference Software automatically accounts for differences in pressure due to height differences between the finger and the heart

,

Detect haemodynamic instability

,

Acumen Hypotension Prediction Index™ (HPI™) Software

,

Unlock predictive decision support through an arterial line

,

Acumen IQ™ Sensor

Learn more

,

Reimagine the way you see haemodynamic monitoring

,

HemoSphere Alta™ Monitor

Learn more

,

Analyze retrospective haemodynamic insights

,

Acumen Analytics™ Software

Learn more

/content/dam/bd-assets/bd-com/en-us/logos/bd/header-bd-logo.svg

Continuous noninvasive blood pressure and advanced haemodynamic monitoring

442794 BD BACTEC™ Myco F/Lytic medium in plastic culture vials 442296 BD BACTEC™ FX40 instrument 442054 BD BACTEC™ Anaerobic Platelet testing medium in plastic culture vials 442053 BD BACTEC™ Aerobic Platelet testing medium in plastic culture vials 442027 BD BACTEC™ Standard Aerobic medium in plastic culture vials 442024 BD BACTEC™ Standard Anaerobic medium in plastic culture vials 442020 BD BACTEC™ Peds Plus medium in plastic culture vials 249560 Vent Aerobic 50 EA
Advanced Patient Monitoring, Advanced Hemodynamic Monitoring, Advanced Hemodynamic Software