Icon to close the modal
Support
Sales
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Modal Close Icon

Capability:

Product Line:

Icon to close thank you modal
Thank you for contacting our sales team!
A sales representive will get in touch with you shortly.
Ordering
Phone Icon
1.714.283.2228
5 a.m. to 4 p.m. PT
Fax Icon
1.714.283.8424
oem@carefusion.com
Customer Service
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Fax Icon
1.800.847.2220

StatLock™ Arterial Select pediatric stabilization device

The StatLock™ Arterial Select Pediatric Stabilization Device is the ultimate refinement in arterial catheter stabilization.

Contact Us
PED_Arterial_Select_hero.jpg
PF10360-PED_Arterial_Select.png
Loading
Overview
  • A new over-the-top retainer, the StatLock™ Arterial Select Pediatric Stabilization Device is second to none in ease of use and performance excellence.
  • The StatLock™ Arterial Select Pediatric Stabilization Device is designed to hold arterial lines in place throughout therapy.
  • The StatLock™ Arterial Select Pediatric Stabilization Device – the new, world standard for stabilization of arterial catheters.
  • Includes tubing (for crisp wave forms), sterile adhesive strips, skin prep and tincture of benzoin.
  • Available with and without stopcock in pediatric sizes.
true
Features and Benefits
StatLock™ Stabilization Devices are a more effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies. The StatLock™ Arterial Select Pediatric Stabilization Device over-the-top retainer secures a prepackaged tubing extension set and accommodates a wide variety of arterial catheters.
Products & Accessories
  • product-image

    StatLock™ Arterial Select Stabilization Device - Pediatric, 8 in Luer Lock Extension Set with Stopcock

Resources
Frequently Asked Questions

Nearly.The StatLock stabilization device is contraindicated in patients with known allergies to adhesives or tapes.

While the StatLock stabilization device is probably appropriate for more than 99% of your patients; some people have skin that simply will not accept an adhesive-based product – their skin is too flaky, too greasy, or too diaphoretic. Use clinical judgment. Just know that where you can use StatLock stabilization device, your clinical and cost outcomes will be dramatically improved.

You do need to extend your insertion site alcohol prep or chlorhexidine prep widely to both sides to cover the securement site. This is a necessary step to cleanse the skin before the StatLock stabilization device application.

BD recommends the use of the skin prep pad included with the StatLock stabilization device. The skin prep provides an acrylic layer that protects the skin and enhances adherence of the anchor pad. Performing both of these steps will maximize product performance.

When you use the skin prep you'll need to allow it to dry for 10 to 15 seconds and make certain it is dry, meaning smooth to the touch – not tacky. Use your clinical judgment based on assessment of the patient's skin. Just remember, when skin prep is not used the StatLock stabilization devices may prematurely lift.

Yes.

  • Always orient the push-tab straight up.
  • Always connect the StatLock stabilization retainer device to the PIV before placing the StatLock stabilization device onto skin.
  • The blue StatLock stabilization device retainer clip is like an upside-down "V". Therefore, do not inadvertently squeeze it closed by compressing both sides. Instead, just hold one side and snap it over the hub of the catheter.

You can use them to:

  • Stabilize the catheter while prepping and securing with the StatLock stabilization device by applying the foam strips over the catheter hub
  • Fashion a J-loop with the IV tubing
  • Form a cushion under your luer lock spin nut
  • For extension sets without luer locks, wrap them around the catheter and the extension set connection for added security
  • Reinforce the StatLock stabilization devices. They are sterile, tape is not.

If you had a tape-secured PIV, then you would have to remove the tape to change the tubing.

StatLock IV Ultra stabilization device

With the StatLock IV Ultra stabilization device you can keep the stabilization device in place while you change tubing. Simply steady the retainer with the thumb and index finger of one hand while unscrewing the extension set. Remove the set. Then, while continuing to brace the retainer, press-fit and screw in your replacement extension set.

StatLock IV Select stabilization device

For StatLock IV Select stabilization device, you will need to replace the StatLock stabilization devices when you remove and replace the tubing – just as you would with tape securement; but this is a rare event offset by StatLock stabilization device advantages.

<p>Nearly.The StatLock stabilization device is contraindicated in patients with known allergies to adhesives or tapes.</p> <p>While the StatLock stabilization device is probably appropriate for more than 99% of your patients; some people have skin that simply will not accept an adhesive-based product – their skin is too flaky, too greasy, or too diaphoretic. Use clinical judgment. Just know that where you can use StatLock stabilization device, your clinical and cost outcomes will be dramatically improved.</p>

<p>You do need to extend your insertion site alcohol prep or chlorhexidine prep widely to both sides to cover the securement site. This is a necessary step to cleanse the skin before the StatLock stabilization device application.</p> <p>BD recommends the use of the skin prep pad included with the StatLock stabilization device. The skin prep provides an acrylic layer that protects the skin and enhances adherence of the anchor pad. Performing both of these steps will maximize product performance.</p> <p>When you use the skin prep you'll need to allow it to dry for 10 to 15 seconds and make certain it is dry, meaning smooth to the touch – not tacky. Use your clinical judgment based on assessment of the patient's skin. Just remember, when skin prep is not used the StatLock stabilization devices may prematurely lift.</p>

<p>Yes.</p> <li>Always orient the push-tab straight up.</li> <li>Always connect the StatLock stabilization retainer device to the PIV before placing the StatLock stabilization device onto skin.</li> <li>The blue StatLock stabilization device retainer clip is like an upside-down "V". Therefore, do not inadvertently squeeze it closed by compressing both sides. Instead, just hold one side and snap it over the hub of the catheter.</li>

<p>You can use them to:</p> <li>Stabilize the catheter while prepping and securing with the StatLock stabilization device by applying the foam strips over the catheter hub</li> <li>Fashion a J-loop with the IV tubing</li> <li>Form a cushion under your luer lock spin nut</li> <li>For extension sets without luer locks, wrap them around the catheter and the extension set connection for added security</li> <li>Reinforce the StatLock stabilization devices. They are sterile, tape is not.</li>

<p>If you had a tape-secured PIV, then you would have to remove the tape to change the tubing.</p> <p><strong>StatLock IV Ultra stabilization device</strong></p> <p>With the StatLock IV Ultra stabilization device you can keep the stabilization device in place while you change tubing. Simply steady the retainer with the thumb and index finger of one hand while unscrewing the extension set. Remove the set. Then, while continuing to brace the retainer, press-fit and screw in your replacement extension set.</p> <p><strong>StatLock IV Select stabilization device</strong></p> <p>For StatLock IV Select stabilization device, you will need to replace the StatLock stabilization devices when you remove and replace the tubing – just as you would with tape securement; but this is a rare event offset by StatLock stabilization device advantages.</p>

true
Reference

Please note, not all products, services or features of products and services may be available in your local area. Please check with your local BD representative.

Please consult product labels, IFU, and package inserts for any indications, contraindications, hazards, warnings, cautions, and instructions for use.

true

BD-19912

Chat with us
Our live chat is available between the hours of 8.30am - 5.00pm EST, Monday - Friday
×