true

PowerPICC SOLO™ Catheter

The versatility of one PICC designed to meet a variety of clinician and patient needs

Background Image
PowerPICC SOLO™ Catheter

Ready to learn more? Let’s have a conversation.

Loading
Overview

Highlights

  • Power injectable
  • Easy identification
  • IV fluid and blood infusion
  • CVP monitoring
  • Simplified care and maintenance
true

*Compared to traditional clamped catheters.

Sherlock 3CG+™
Tip Confirmation System

Compatible with Sherlock 3CG+™ Tip Confirmation System

The PowerPICC™ SOLO family of products can be paired with Sherlock 3CG+™ Tip Confirmation for bedside placement and real-time tip confirmation.

Ready to learn more?

PowerPICC SOLO™ Catheter
Ready to learn more? Let’s have a conversation.
Overview

Power. Saline. One

PowerPICC SOLO™ Catheters provide the efficiency of power injection combined with simplified care and maintenance.

Features & benefits

The PowerPICC SOLO™ Catheter with proximal valve technology provides clamp free short and long-term infusion with a maximum injection rate of 300 psi, 5 mL per second. It is trimmable and comes in single, double and triple lumen configurations with the option of Sherlock 3CG+™ Tip Confirmation System tracking and navigation for optimal catheter placement.

Dual and triple-lumen design

Allows for multiple infusion therapies and can be used for blood sampling, which reduces the need for additional IV access and the accompanying needlesticks

Power injection

PowerPICC SOLO™ Catheters allow injection of contrast media for CECT (contrast enhanced computed tomography) scans with a maximum rate of 5 mL/sec

Reduced flushing protocols

To a minimum of one time a week

CVP montoring

All PowerPICC SOLO™ Catheters are indicated for CVP monitoring.
It is recommended that a catheter lumen of 20 G or larger is used

Strong and durable

PowerPICC™ Catheters are polyurethane catheters that help to provide strength and durability

Clearly labeled depth markings

Every 1 cm on catheter bodies

55 cm length

Distally trimmable PICC

Kink-resistantPowerPICC SOLO™ Catheters feature a reverse taper hub, which taponades the insertion site and provides kink-resistance
Extension leg labelEasy PICC identification after catheter placement
Gauge sizeClearly labeled on hub of each extension leg
Fewer flushing complicationsMay limit risk associated with heparin use (HIT)
Excellent ClearanceValve clears after recommended saline flush
Related solutions
  • Card Image

    Sherlock 3CG+™ Tip Confirmation System 

    Real-time tip location and confirmation technology

    Learn More

  • Card Image

    SiteRite™ 9 Ultrasound System

    Ultrasound and imaging technologies help you visualize vessels, needle trajectory and final catheter tip location

    Learn More

  • PowerPICC Catheter

    PowerPICC™ Catheters

    Combine the efficiency of peripherally inserted central catheter (PICC) access and power injection into one catheter

  • Card Image

    PowerPICC Provena™ Catheters

    Smaller-diameter* PICCs that maintain high performance for infusion therapy 

  • Card Image

    PowerPICC Provena™ SOLO™ Catheters

    Smaller-diameter* PICCs that maintain high performance for infusion therapy without the need for heparin flush solution

  • Card Image

    BD Introsyte Autoguard™ Shielded Introducer

    Features a unique push-button shielding mechanism, which the clinician activates to quickly retract into the safety barrel

    Learn More

  • Card Image

    BD Introsyte-N Autoguard™ Shielded Introducer

    Featuring a notched needle technology that enables rapid visualization of blood return among the catheter shaft

    Learn More

*Size comparison in relation to the PowerPICC™ Catheters of the same lumen configuration.

Ready to learn more?

PowerPICC SOLO™ Catheter
Ready to learn more? Let’s have a conversation.
Overview

Fit for veins

Combining all the features of PowerPICC™ SOLO™ with PowerPICC™ FT Catheters,  the PowerPICC SOLO™ FT Catheter is designed with a smaller diameter, more flexible midsection to better !t within the patient's veins.

Catheter design

Designed from the insertion site to the central venous system

PowerPICC SOLO™ FT Catheters features a reverse taper to help plug the insertion site and provide kink resistance1. It also features a more flexible midsection with a smaller diameter for dwelling the small peripheral veins of the upper arm and a larger distal tip to provide catheter stability in the central vessels.

    Features & benefits

    Optimized lumens

    Designed to deliver high pump and gravity flow rates with low pressure comparable to the 5 French dual lumen PowerPICC™ Catheter

    Maximal barrier

    PowerPICC™ Catheter full procedural tray includes maximal barrier components helping to enable clinicians to meet clinical guidelines

    Related solutions
    • Card Image

      Sherlock 3CG+™ Tip Confirmation System 

      Real-time tip location and confirmation technology

      Learn More

    • Card Image

      SiteRite™ 9 Ultrasound System

      Ultrasound and imaging technologies help you visualize vessels, needle trajectory and final catheter tip location

      Learn More

    • PowerPICC Catheter

      PowerPICC™ Catheters

      Combine the efficiency of peripherally inserted central catheter (PICC) access and power injection into one catheter

    • Card Image

      PowerPICC Provena™ Catheters

      Smaller-diameter* PICCs that maintain high performance for infusion therapy 

    • Card Image

      PowerPICC Provena™ SOLO™ Catheters

      Smaller-diameter* PICCs that maintain high performance for infusion therapy without the need for heparin flush solution

    • Card Image

      BD Introsyte Autoguard™ Shielded Introducer

      Features a unique push-button shielding mechanism, which the clinician activates to quickly retract into the safety barrel

      Learn More

    • Card Image

      BD Introsyte-N Autoguard™ Shielded Introducer

      Featuring a notched needle technology that enables rapid visualization of blood return among the catheter shaft

      Learn More

    *Size comparison in relation to the PowerPICC™ Catheters of the same lumen configuration.

    Ready to learn more?

    PowerPICC SOLO™ Catheter
    Ready to learn more? Let’s have a conversation.
    Overview
    1. Bae HS, Kim KY, Han YM. Comparison of complications between reverse-tapered and nontapered peripherally inserted central catheters. PLoSOne. 2023 May 4;18(5):e0285445. doi: 10.1371/journal.pone.0285445. PMID: 37141269.

    Overview

    When infusion therapy delivery is critical

    Infusion therapy delivery is critical to patient care. The 5 French Triple Lumen PowerPICC™ High Flow (HF) Catheters flow rates deliver prescribed therapy in the triple lumen PICC without disrupting gravity or pump infusions.

    Features & benefits

    Aligns with industry recommendations

    At only 5 French in diameter, the triple lumen PowerPICC SOLO™* High Flow Catheter aligns with the 2024 Infusion Nursing Society (INS) recommendation of “the least invasive VAD with the smallest outer diameter and fewest number of lumens needed for the prescribed therapy is selected.”1

    Small French size

    Facilitates placement in smaller veins and mitigates the risk of thrombosis2

    Power injection

    PowerPICC™ Catheters allow injection of contrast media for CECT (contrast-enhanced computed tomography) scans with a maximum rate of 5 mL/sec

    Triple lumens

    Enable multiple infusion therapies and blood sampling

    Open-ended catheter design

    Allows for central venous pressure (CVP) monitoring

    Available in clamped or valved options

    Blood collection

    PowerPICC™ is indicated for blood sampling on 4 French or larger catheters

    StatLock™ Stabilization Device compatibleThe catheter features a winged hub compatible with the Statlock™ Stabilization Device, eliminating the need for sutures
    CVP monitoringAll PowerPICC™ Catheters are indicated for CVP monitoring. It is recommended that a catheter lumen of 20 G or larger is used
    Related solutions
    • Card Image

      Sherlock 3CG+™ Tip Confirmation System 

      Real-time tip location and confirmation technology

      Learn More

    • Card Image

      SiteRite™ 9 Ultrasound System

      Ultrasound and imaging technologies help you visualize vessels, needle trajectory and final catheter tip location

      Learn More

    • PowerPICC Catheter

      PowerPICC™ Catheters

      Combine the efficiency of peripherally inserted central catheter (PICC) access and power injection into one catheter

    • Card Image

      PowerPICC Provena™ Catheters

      Smaller-diameter* PICCs that maintain high performance for infusion therapy 

    • Card Image

      PowerPICC Provena™ SOLO™ Catheters

      Smaller-diameter* PICCs that maintain high performance for infusion therapy without the need for heparin flush solution

    • Card Image

      BD Introsyte Autoguard™ Shielded Introducer

      Features a unique push-button shielding mechanism, which the clinician activates to quickly retract into the safety barrel

      Learn More

    • Card Image

      BD Introsyte-N Autoguard™ Shielded Introducer

      Featuring a notched needle technology that enables rapid visualization of blood return among the catheter shaft

      Learn More

    *Size comparison in relation to the PowerPICC™ Catheters of the same lumen configuration.

    Ready to learn more?

    PowerPICC SOLO™ Catheter
    Ready to learn more? Let’s have a conversation.
    Overview
    1. Nickel B, Gorski L, Kleidon T, et al. Infusion Therapy Standards of Practice, 9th Editioin. J Infus Nurs. 2024;47(1S Suppl 1):S1-S285.doi:10.1097/NAN.0000000000000532
    2. Cadacio C. Nachamkin I. A Novel Needle-Free Blood Draw Device for Sample Collection From Short Peripheral Catheters. J Infus Nurs. 2017:40(3):156-162.doi:10.1097/NAN.0000000000000222.
    Products & Accessories