true

Vascushunt™ II Silicone Carotid Shunt

FloTrac™ Sensor example
Loading
Overview

Vascushunt™ II Silicone Carotid Endarterectomy Shunt

Flexibility in shunting with a safety balloon and choice of sizes.

Safety balloon

  • The incorporation of a safety balloon has been developed and is utilized to reduce the possibility of damaging the internal carotid artery.
  • If the internal carotid balloon inadvertently overinflates, excess pressure is diverted to the safety balloon, reducing pressure in the internal balloon to help minimize the possibility of vessel trauma.*
     

Flexibility

  • Vascushunt™ II Silicone Carotid Endarterectomy Shunt is designed to provide flexibility for ease-of-use during the procedure.
     

Multiple sizes and lengths

  • Available in 8F, 9F and 11F in both outlying 30 cm and inlying 15 cm lengths, with stopcocks to meet a variety of clinical needs.
     

Caution: Care must be taken at all times to prevent over-inflation of the balloons, as it may result in obstruction of blood flow and injury to the vessel.

Vascushunt™ II Silicone Endarterectomy Shunt is not made with natural rubber latex.

Manufactured by Lucas Medical, Inc. Distributed by Edwards Lifesciences LLC.

*It has been reported that human internal carotid arteries can rupture at pressures of 20 psi. The safety balloon is intended to prevent the pressure from reaching this level by inflating at a level that is less than 20 psi.

Related Products
Atraumatic Occlusion

Atraumatic Occlusion

Occlusion

Occlusion

Clot Management

Clot Management

Electronic Instructions for Use (eIFUs)
Resources

Let's have a conversation

Fill out our form to have one of our pediatrics specialists contact you.

Vascushunt II Silicone Carotid Shunt

CAUTION: Federal (United States) law restricts this device to sale by or on the order of a physician.
See instructions for use for full prescribing information, including indications, contraindications, warnings, precautions and adverse events.

true
true
VascuShunt™ II Silicone Carotid Shunt /content/dam/bd-assets/bd-com/en-us/images/product-family/advanced-patient-monitoring/vascular/vascushunt-carotid-shunt-thumb.jpg BD Vascushunt™ II silicone carotid endarterectomy shunt Vascushunt™ II

Atraumatic Occlusion

,,

Occlusion

,

Learn more

,

Clot Management

,
/content/dam/bd-assets/bd-com/en-us/logos/bd/header-bd-logo.svg 1878001 Chambre implantable PowerPort™ M.R.I.™ 1878000 Chambre implantable PowerPort™ M.R.I.™ 1859601 Chambre implantable PowerPort™ M.R.I.™ 1859600 Chambre implantable PowerPort™ M.R.I.™ 1809601 Chambre implantable PowerPort™ M.R.I.™ 1809600 Chambre implantable PowerPort™ M.R.I.™ 1808071 Chambre implantable PowerPort™ M.R.I.™ 1808070 Chambre implantable PowerPort™ M.R.I.™ 1808001 Chambre implantable PowerPort™ M.R.I.™ 1808000 Chambre implantable PowerPort™ M.R.I.™
VascuShunt™ II carotid shunt, silicone carotid shunt, Edwards Lifesciences vascular solutions, carotid endarterectomy shunt, temporary vessel perfusion, vascular surgery tools, carotid artery shunt device, surgical shunt for endarterectomy, vessel protection during surgery, carotid shunt with safety balloon