Icon to close the modal
Support
Sales
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Modal Close Icon
Sales Form
Please fill out the form and a sales representative will get in touch with you.

Capability:

Product Line:

Icon to close thank you modal
Thank you for contacting our sales team!
A sales representive will get in touch with you shortly.
Ordering
Phone Icon
1.800.556.6756
BDISurgery@bd.com
Onsite Visiting
Location Icon
100 Crossings Boulevard Warwick, Rhode Island 02886 United States
Customer Service
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Monday to Friday 8:15 AM to 6:00 PM EST
Fax Icon
1.800.531.4124
Custserv.davol@bd.com
Shipping a Product Back
Location Icon
100 Crossings Boulevard, Warwick, Rhode Island 02886, United States

Sepramesh™ IP Composite for Ventral Hernia Repair

Contact Us navigation arrow
Carousel Image
Loading
tabs dropdown arrow
Overview

Combines the strength of polypropylene mesh with a bioresorbable hydrogel coating for ventral hernia repair.

The strength of a permanent mesh with the effectiveness of a bioresorbable coating.

Sepramesh™ IP Composite is a polypropylene mesh with a hydrogel safety coating, which resorbs within 30 days providing visceral protection during the critical healing period.1

Sepramesh™ IP Composite is built on the foundation of the proven Sepra® technology, with 12 years of clinically demonstrated success. The parietal side of the mesh consists of monofilament polypropylene which encourages rapid tissue ingrowth and incorporation for a strong ventral hernia repair. The visceral side of the mesh is covered with a unique bioresorbable hydrogel coating that minimizes tissue attachment. Bioresorbable fibers reinforce mesh strength and bind the mesh to the hydrogel coating.

Features and Benefits

During the incorporation of the mesh into the abdominal wall, these fibers – along with the hydrogel coating – are resorbed, leaving less permanent foreign material in the body. In addition, Sepramesh™ IP Composite comes in a variety of sizes, but can also be cut and tailored without fraying or unraveling allowing it to be customized for each individual patient.

Efficient

Efficient for a custom hernia repair

  • Creating a customized hernia repair is easy with Sepramesh™ IP Composite. Various rectangle sizes allow you to create the size and shape you need to cover the defect and allow for adequate mesh overlap.
 
  • In addition, the ability to tailor the mesh may reduce the number of item codes that need to be ordered - minimizing inventory. Various rectangle sizes allow you to create the size and shape you need to cover the defect and allow for adequate mesh overlap.
 
  • Additionally,  preclinical data demonstrated that the protective coating is reabsorbed within 30 days, resulting in a permeable repair.*
Effective

Effective for a strong ventral hernia repair

The uncoated monofilament parietal side of Sepramesh™ IP Composite stimulates a fast fibrotic response. This results in strong tissue incorporation into the abdominal wall, which provides a strong long-term repair, minimizing recurrences and the need for permanent transfixation sutures.

Additionally, the hydrogel barrier minimizes tissue attachment to the prosthesis.

Secure fixation

The SorbaFix™ Absorbable Fixation System provides secure fixation with Sepramesh™ IP Composite. Threaded, hollow core allows for tissue ingrowth through the interior of the fastener.

 Proven

Proven solution for customized hernia repair

  • Protective coating is reabsorbed within 30 days, resulting in a permeable repair.
  • Mesh is easily cut to customize shape and size.

 

Sepramesh™ IP Composite is Built on Two Clinically Proven Technologies

 Sepramesh™ IP Composite – A Clinical Study

 A Single-Arm, Single-Center, Retrospective Study with Prospective Follow-Up of Laparoscopic Ventral Hernia Repair Utilizing the Bard Sepramesh™ IP Composite.

 Andrew Archer, DO, Stephen Fleischer, DO, Rhett Lohman, DO, Edward Caldwell, DO. Grandview Medical Center, Dept. of Surgery, Dayton, OH.

Click here to download the study poster for more details.

Reference

* Preclinical data on file. Results may not correlate to performance in humans.

1. Sasse KC, Lim DCL, Brandt J, “Long-term Durability and Comfort of Laparoscopic Ventral Hernia Repair”. Journal of the Society of Laparoendoscopic Surgeon, 2012 July-September, 16(3): 380-386

INDICATIONS

Sepramesh™ IP Bioresorbable Coating / Permanent Mesh is indicated for use in the reconstruction of soft tissue deficiencies, such as for the repair of hernias.

CONTRAINDICATIONS

Literature reports there may be a possibility for adhesion formation when the polypropylene is placed in contact with the bowel or viscera. Do not use Sepramesh™ IP Bioresorbable Coating/Permanent Mesh in infants or children, whereby future growth will be compromised by use of such mesh material. Do not use Sepramesh™ IP Bioresorbable Coating/Permanent Mesh for the reconstruction of cardiovascular defects.

WARNINGS

Ensure proper orientation; the coating side of the prosthesis should be oriented against the bowel or sensitive organs. Do not place the polypropylene side against the bowel. There may be a possibility for adhesion formation when the prosthesis is placed in direct contact with the bowel or viscera.

ADVERSE REACTIONS

Possible complications include seroma, adhesions, hematomas, inflammation, extrusion, fistula formation and recurrence of the hernia or soft tissue defect.

Please consult package insert for more detailed safety information and instructions for use.

true
Products & Accessories
  • product-image

    Sepramesh™ IP Composite, Rectangle, 8" x 12" (20.3 cm x 30.5 cm)

  • product-image

    Sepramesh™ IP Composite, Rectangle, 12" x 14" (30.5 cm x 35.6 cm)

  • product-image

    Sepramesh™ IP Composite , Rectangle, 3" x 6" (7.6 cm x 15.2 cm)

  • product-image

    Sepramesh™ IP Composite, Rectangle, 4" x 8" (10.2 cm x 20.3 cm)

  • product-image

    Sepramesh™ IP Composite, Rectangle, 6" x 8" (15.2 cm x 20.3 cm)

References

* Preclinical data on file. Results may not correlate to performance in humans.

1. Sasse KC, Lim DCL, Brandt J, “Long-term Durability and Comfort of Laparoscopic Ventral Hernia Repair”. Journal of the Society of Laparoendoscopic Surgeon, 2012 July-September, 16(3): 380-386

INDICATIONS

Sepramesh™ IP Bioresorbable Coating / Permanent Mesh is indicated for use in the reconstruction of soft tissue deficiencies, such as for the repair of hernias.

CONTRAINDICATIONS

Literature reports there may be a possibility for adhesion formation when the polypropylene is placed in contact with the bowel or viscera. Do not use Sepramesh™ IP Bioresorbable Coating/Permanent Mesh in infants or children, whereby future growth will be compromised by use of such mesh material. Do not use Sepramesh™ IP Bioresorbable Coating/Permanent Mesh for the reconstruction of cardiovascular defects.

WARNINGS

Ensure proper orientation; the coating side of the prosthesis should be oriented against the bowel or sensitive organs. Do not place the polypropylene side against the bowel. There may be a possibility for adhesion formation when the prosthesis is placed in direct contact with the bowel or viscera.

ADVERSE REACTIONS

Possible complications include seroma, adhesions, hematomas, inflammation, extrusion, fistula formation and recurrence of the hernia or soft tissue defect.

Please consult package insert for more detailed safety information and instructions for use.

true
Resources
References

* Preclinical data on file. Results may not correlate to performance in humans.

1. Sasse KC, Lim DCL, Brandt J, “Long-term Durability and Comfort of Laparoscopic Ventral Hernia Repair”. Journal of the Society of Laparoendoscopic Surgeon, 2012 July-September, 16(3): 380-386

INDICATIONS

Sepramesh™ IP Bioresorbable Coating / Permanent Mesh is indicated for use in the reconstruction of soft tissue deficiencies, such as for the repair of hernias.

CONTRAINDICATIONS

Literature reports there may be a possibility for adhesion formation when the polypropylene is placed in contact with the bowel or viscera. Do not use Sepramesh™ IP Bioresorbable Coating/Permanent Mesh in infants or children, whereby future growth will be compromised by use of such mesh material. Do not use Sepramesh™ IP Bioresorbable Coating/Permanent Mesh for the reconstruction of cardiovascular defects.

WARNINGS

Ensure proper orientation; the coating side of the prosthesis should be oriented against the bowel or sensitive organs. Do not place the polypropylene side against the bowel. There may be a possibility for adhesion formation when the prosthesis is placed in direct contact with the bowel or viscera.

ADVERSE REACTIONS

Possible complications include seroma, adhesions, hematomas, inflammation, extrusion, fistula formation and recurrence of the hernia or soft tissue defect.

Please consult package insert for more detailed safety information and instructions for use.

true
Chat with us
Our live chat is available between the hours of 8.30am - 5.00pm EST, Monday - Friday
×