{"AlternateComparison":false,"RelatedProducts":true,"Specification":true,"FeatureBenefit":false}
Ventrio™ Synthetic mesh Ventrio™ ST Hernia Patch

Ventrio™ ST Hernia Patch, Small Oval, 3.1 in x 4.7 in (8.0 cm x 12.0 cm)

Icon to close the modal
Support
Sales
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Modal Close Icon

Capability:

Product Line:

Icon to close thank you modal
Thank you for contacting our sales team!
A sales representative will get in touch with you shortly.
Ordering
Phone Icon
1.800.556.6756
BDISurgery@bd.com
Onsite Visiting
Location Icon
100 Crossings Boulevard Warwick, Rhode Island 02886 United States
Customer Service
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Monday to Friday 8:15 AM to 6:00 PM EST
Fax Icon
1.800.531.4124
Custserv.davol@bd.com
Shipping a Product Back
Location Icon
100 Crossings Boulevard, Warwick, Rhode Island 02886, United States
Overview

The benefits of a laparoscopic repair through an open incision featuring an absorbable barrier based on Sepra® Technology.1

The Ventrio™ ST Hernia Patch is a monofilament polypropylene mesh with SorbaFlex™ Memory Technology and an absorbable barrier based on Sepra® Technology.

true
Features and Benefits
Promotional Story
false
References
  1. Preclinical data on file at C. R. Bard. Results may not correlate to performance in humans.
  2. Iannitti, D. et. al. “Technique and Outcomes of Abdominal Incisional Hernia Repair Using a Synthetic Composite Mesh: A Report of 455 cases.” Journal of the American College of Surgeons. 2008 Jan; 206 (1):83-8.
  3. Majercik, S. et al. “Strength in tissue attachment to mesh after ventral hernia repair with synthetic composite mesh in a porcine model.” Surg Endosc (2006) 20: 1671-1674.

INDICATIONS

The Ventrio™ ST Hernia Patch is indicated for use in the reinforcement of soft tissue, where weakness exists, in procedures involving soft tissue repair, such as for the repair of hernias.

CONTRAINDICATIONS

1. Do not use this mesh in infants, children, or pregnant women, whereby future growth may be compromised by the use of such mesh materials.
2. The use of this mesh has not been studied in breastfeeding or pregnant women.
3. Do not use this mesh for the reconstruction of cardiovascular defects.
4. Literature reports that there may be a possibility for adhesion formation when the polypropylene is placed in contact with the bowel or viscera.

WARNINGS

1. The use of any permanent mesh or patch in a contaminated or infected wound could lead to fistula formation and/or extrusion of the mesh.
2. If an infection develops, treat the infection aggressively. Consideration should be given regarding the need to remove the mesh. An unresolved infection may require the removal of the mesh.
3. If the unused mesh has been in contact with instruments or supplies used on a patient or contaminated with bodily fluids, discard with care to prevent risk of transmission of viral infections.
4. To prevent recurrences when repairing hernias, the mesh should be sized with appropriate overlap for the size and location of the defect, taking into consideration any additional clinical factors applicable to the patient. Careful attention to mesh fixation placement and spacing will help prevent excessive tension or gap formation between the mesh and fascial tissue.
5. This mesh is supplied sterile. Inspect the packaging to be sure it is intact and undamaged prior to use.
6. This mesh has been designed for single use only. Reuse, resterilization, reprocessing and/or repackaging may compromise the structural integrity and/or essential material and design characteristics that are critical to the overall performance of the mesh and may lead to mesh failure which may result in injury to the patient. Reuse, reprocessing, resterilization, or repackaging may also create a risk of contamination of the mesh and/or cause patient infection or cross infection, including, but not limited to, the transmission of infectious diseases from one patient to another. Contamination of the mesh may lead to injury, illness, or death of the patient or end user.
7. This mesh should be used once the exterior foil pouch has been opened. Do not store for later use. Unused portions of the mesh should be discarded.
8. Ensure proper orientation; the bioresorbable coated side of the mesh should be oriented against the bowel or sensitive organs. Do not place the polypropylene side against the bowel. There may be a possibility for adhesion formation when the mesh is placed in direct contact with the bowel or viscera.
9. Do not cut or reshape the Ventrio™ ST Hernia Patch, as this could impact its effectiveness. Care should be taken not to cut or nick the SorbaFlex™ PDO monofilament during insertion or fixation. If the SorbaFlex™ PDO monofilament is cut or damaged, additional complications may include but are not limited to, bowel or skin perforation and infection.
10. Follow proper folding techniques for all patches as described in these Instructions for Use as other folding techniques may compromise the SorbaFlex™ PDO monofilament (Figure 2).
11. To ensure a strong repair, the mesh should be secured with tacks or sutures through the polypropylene mesh structure or full mesh. Suturing or tacking on the edge of the mesh alone is not recommended.
12. This mesh is not for the use of repair of pelvic organ prolapse via transvaginal approach.
13. This mesh is not for the use of treatment of stress urinary incontinence.

PRECAUTIONS

1. Please read all instructions prior to use.
2. Only physicians qualified in the appropriate surgical techniques should use this mesh.
3. Care should be taken not to cut or nick the SorbaFlex™ PDO monofilament during fixation.
4. The safety and effectiveness of Ventrio™ ST Hernia Patch has not been evaluated in clinical studies in the presence of malignancies in the abdominopelvic cavity.

ADVERSE REACTIONS

Possible complications include, but are not limited to, seroma, adhesions, hematomas, pain, infection, inflammation, extrusion, erosion, migration, fistula formation, allergic reaction, and recurrence of the hernia or soft tissue defect. If the SorbaFlex™ PDO monofilament is cut or damaged during insertion or fixation, additional complications may include bowel or skin perforation and infection.

Please consult package insert for more detailed safety information and instructions for use.

true
Specification

GTIN - Case

00801741031526

1


Quantity

1/cs


Dimensions

Small Oval 3.1" x 4.7" (8.0cm x 12.0cm)

GTIN

GTIN - Case 00801741031526 1

Packaging

Quantity 1/cs

Product Basic Specification

Dimensions Small Oval 3.1" x 4.7" (8.0cm x 12.0cm)
References
false
Electronic Instructions for Use (eIFUs)
Resources
References
false
Frequently Asked Questions
false
References
false
Related Products
Sort by:
References
false
Product Complaints
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Things to Consider

If you are a patient or end user, you can contact us yourself, or you may have your caregiver or your physician do that for you. To help us process your
information quickly and effectively, please contact our customer complaints
team.

To better facilitate our investigation, please include the following information in your reporting:


  • Product Name and/or Catalog Number
  • Lot Number or Serial Number
  • Any injuries and/or harm?
  • What is the issue you experienced?
  • Is the actual sample or sample representative available? (If possible, please send affected sample)
  • Contact name and phone number
Product Recalls
Literature Icon
Recall Notifications

These recall notices provide current information on medical device recalls.

Learn more
References
false
false