Overview

Protect what matters.
Sterility. Standards. Safety.

When patient safety is involved, port access is never just another task. It requires attention to detail, and consistency at each step.

BD® Port Access Kits and BD® AllPoints™ Port Access Systems combine essential port access procedure components from the port access market leader into one sterile, streamlined and convenient kit—designed to reduce port access procedure variability and promote standard compliance for each patient, in each port access procedure.

 

AllPoints™ Port Access System

Get to know the only all-in-one port access system that is organized in a step-by-step sequential layout to aid clinicians in their efforts toward consistency of care and integrates the needle directly within the kit.

    BD® Port Access Kits

    An all-in-one convenient solution with components organized to promote standardized, sterile “best practices” for port access-related procedures.

      Solutions you can rely on

      Blue Star Icon
      Market-leading port access

      BD is the port access market leader, and is the only major manufacturer to offer an all-inclusive port access kit that integrates the infusion needle directly within the kit.

      Blue Hand Heart Icon
      Designed to promote consistency of care

      BD® Port Access Kits and AllPoints™ Port Access Systems are designed to be a simple and effective way to standardize the port access procedure process and to promote compliance with guidelines for sterile port access.

      Hand Icon
      Convenient

      Provides the convenience of combining essential port access procedure components, including the port access needle, in a single package.

      Blue Checkmark Icon
      Step-by-step organization

      A procedural checklist is included in every kit to facilitate sterile technique, guidance for the clinician through the procedural steps and tracking of port access procedure.

      Standardize your port access practice with support from BD.

      BD® Port Access Kits and Needles
      Ready to learn more? Let’s have a conversation.

      BD-66999 (07/25)

      CLABSI risk and the role of best practices

      In port access, compliance with best practice is critical

      When it comes to port access, every step matters. Central-line bloodstream infections (CLABSIs) remain a significant risk, with as many as 250,000 CLABSIs occurring annually in the U.S.¹ Of the patients who develop a CLABSI, as many as 1 in 4 may not survive.²

      To address this risk, the Infusion Nurses Society (INS) recommends following a standard Aseptic Non-Touch Technique (ANTT®) designed to help reduce the likelihood of infections.

      INS Standards also note the use of single-use kits and barriers to help establish an aseptic field.

      Aligning practice 
to guidelines

      All-in-one port access designed to promote best practices

      BD® AllPoints™ Port Access Systems bring together the key components needed to help support aseptic technique and promote consistency with port access guidelines.

      Each kit is sterile, organized in procedural sequence and designed to aid clinicians in following ANTT® and INS standards across teams and shifts. Procedural checklists are included to help guide consistent technique and support standardization in practice.

      How AllPoints™ Kits support best practices

      Each item within the all-in-one, step-by-step AllPoints™ Port Access System is designed to promote compliance with healthcare best practices and guidelines for port access.

      Description

      How AllPoints™ Systems align

      Wear…a mask (both clinician and patient) to reduce the risk of droplet transmission of oropharyngeal flora.1

       

      Borrowing from INS Standard 27, two sterile masks (one for the clinician and one for the patient)

      Description

      How AllPoints™ Systems align

      Use an alcohol-based hand rub (ABHR) containing at least 60% ethanol or 70% isopropyl alcohol routinely for hand hygiene.1

      Ensure that supplies necessary for adherence to hand hygiene are readily accessible in all areas where patient care is being delivered.1

      Purell® Advanced Hand Sanitizer gel packs

      Description

      How AllPoints™ Systems align

      Don sterile gloves to palpate or locate port site after skin antisepsis and prior to insertion of non-coring needle.1

      Two sets of sterile gloves (one for preparation and one for access)

      Description

      How AllPoints™ Systems align

      Critical Aseptic Field: A large sterile drape/barrier. Used to ensure asepsis; all procedure equipment is placed upon the drape and protects multiple and often large Key-Parts collectively.

      Full-size sterile field drape unfolds into a sequential layout to enable the creation of an aseptic field.

      Description

      How AllPoints™ Systems align

      Perform skin antisepsis prior to port access and allow skin antiseptic agent to fully dry prior to port access.

      BD® ChloraPrep™ Patient Preoperative Skin Preparation with Sterile Solution™

      Description

      How AllPoints™ Systems align

      Use a single-use applicator containing an antiseptic solution.

      BD® ChloraPrep™ Patient Preoperative Skin Preparation with Sterile Solution™

      Description

      How AllPoints™ Systems align

      Flush and lock the port to assess function and maintain patency.
      1. Use at least 10 mL of 0.9% sodium chloride (adult).
      2. Use of 0.9% sodium chloride alone may be as effective as heparin in maintaining patency.

      Sterile field-ready, pre-filled flush syringe with peel-away packaging

      Description

      How AllPoints™ Systems align

      Use commercially manufactured prefilled flush syringes (when available) to reduce the risk of catheter-associated bloodstream infection (CABSI) and device failure, save time for syringe preparation, and aid optimal flushing technique and objectives.

      Sterile field-ready, pre-filled flush syringe with peel-away packaging

      Description

      How AllPoints™ Systems align

      Access the port with the smallest-gauge non-coring needle to accommodate the prescribed therapy; use of a safety engineered non-coring needle is recommended and required in some jurisdictions.

      Confirm that a port and the non-coring needle are indicated for power injection before using it for this purpose.

      Non-coring needles are available in a wide variety of gauge sizes for use with implanted ports.
       
      For ports verified as power-injectable, BD® PowerLoc™ and PowerLoc™ Max Safety Power Injectable Infusion Sets are power injection–rated for optimal protection.

      Description

      How AllPoints™ Systems align

      Consider use of a needle insertion assistive device, which may improve first-attempt success with insertion of the non-coring needle into the port.

      BD® Amanda™ Port Stabilizer is designed to aid access when inserting the infusion needle into single-port devices.

      Description

      How AllPoints™ Systems align

      Consider chlorhexidine-containing dressings in adults and patients over 2 months of age. Guidelines for oncology patients suggest use of a chlorhexidine- containing dressing around the needle insertion site based on duration of infusions exceeding 4 to 6 hours.

      Configurations include additional CHG disc and gel pad options, including the BD® GuardIVa™ Antimicrobial Hemostatic IV Dressing.

      Description

      How AllPoints™ Systems align

      Prepare skin for optimal skin health and dressing adherence.

      Sterile skin-protectant prep pad

      Description

      How AllPoints™ Systems align

      Use a transparent semipermeable membrane (TSM) dressing that covers the non-coring needle and access site when the port is accessed.

      Secure the non-coring needle to reduce the risk for needle dislodgement and subsequent risk for infiltration/extravasation (eg, sterile tape strips), assuring protection of skin integrity around the insertion site.

      BD® Sentrinex™ 3D Port Dressing

      Description

      How AllPoints™ Systems align

      A sterile dressing, combined or integrated with a securement device appropriate for patient’s condition and patient preference, is maintained on all peripheral and central VADs to protect the site, provide a microbial barrier, and promote skin health and VAD securement.

      BD® Sentrinex™ 3D Port Dressing

      Experience how the AllPoints™ System can help you implement best practices.

      BD® Port Access Kits and Needles
      Ready to learn more? Let’s have a conversation.
      References
      1. Raad I, Hanna H, Maki D. Intravascular catheter-related infections: advances in diagnosis, prevention, and management. Lancet Infect Dis. 2007;7(10):645-657. doi:10.1016/S1473-3099(07)70235-9
      2. Centers for Disease Control and Prevention (CDC). Making health care safer: Reducing blood stream infections. CDC Vital Signs. March 2011. Accessed June 10, 2025.

      AllPoints™ Port Access System

      Infusion needles and components

      • miniloc-thumbnail.jpg

        The safety mechanism on the MiniLoc™ Safety Infusion Set is an easy to use, single step safety activation. The needle point safety is designed to help reduce the risk of needlestick injuries.

      • powerloc-thumbnail.jpg

        The PowerLoc™ Safety Infusion Set is a winged power  injectable port access needle with a passive needle tip safety designed to protect against healthcare worker needlestick injuries.*

         

        *Bench test results may not necessarily be indicative of clinical performance.

      • safestep-thumbnail.jpg

          

        The SafeStep™ Huber Needle Set increases access site visibility due to a clear plastic base. The SafeStep™ safety mechanism requires no additional technique when removing the needle from a port.

         

      • powerloc-max-thumbnail.jpg

          

        The PowerLoc™ Max Safety Infusion Set is a non-winged power-injectable port access needle with a passive needle tip safety designed to help protect against healthcare worker needlestick injuries.

      • sentrinex-thumbnail.jpg

         

         

        Created specifically for port access, this 3D domed dressing is designed to fit over most needle access devices and lay flat against the skin.

         

      • guardiva-thumbnail.jpg

        The chlorhexidine gluconate (CHG) in the GuardIVa™ Antimicrobial Hemostatic IV Dressing is a well-known antiseptic agent with broad spectrum antimicrobial and antifungal activity.

      Resources
      EIFUs
      BD Port Access Kits and Needles BD BD® Port Access Kits and Needles /content/dam/bd-assets/bd-com/en-us/logos/bd/header-bd-logo.svg

      Featuring the BD® AllPoints™ Port Access System—
an all-in-one solution designed to simplify procedures and promote consistency of care

      0606560 Hickman™ triple lumen catheter with peel-apart introducer 0600650 Hickman™ triple lumen catheter with peel-apart introducer 0600620 Hickman™ dual lumen catheter with peel-apart introducer 0600570 Hickman™ dual lumen catheter with peel-apart introducer 0600560 Hickman™ single lumen catheter with peel-apart introducer 0600540 Broviac™ single lumen catheter with peel-apart introducer 0600520 Broviac™ single lumen catheter with peel-apart introducer 0600350 Hickman™ dual lumen catheter; cutdown procedure tray 0600310 Hickman™ dual lumen catheter; cutdown procedure tray 0600120 Broviac™ single lumen catheter; cutdown procedure tray 0600060 Broviac™ single lumen catheter; cutdown procedure tray 0600040 Broviac™ single lumen catheter; cutdown procedure tray